GARRISON, TX —
OSHA Inspection: MKS SERVICES LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of MKS SERVICES LLC in 1700 N FM 95, GARRISON, TX 75946 (NAICS 213111). OSHA activity number 345953848.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MKS SERVICES LLC
- Site address
- 1700 N FM 95
- City
- GARRISON
- State
- TX
- ZIP
- 75946
- Mailing
- 6389 US HIGHWAY 79 SOUTH, PALESTINE, TX 75801
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Sep 30, 2022
- Abate by
- Oct 20, 2022
- Penalty
- Initial $13,052 · Current $10,442 Reduced
General-duty citation text
OSH ACT of 1970 Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard: On or about May 11, 2022, at a well site between 1700 - 1738 FM 95 Garrison TX, 75946, employees working on a Cooper brand work over rig (Rig #5), were exposed to the hazard of struck-by. The rig was not anchored in accordance with structural design by a qualified person using accepted engineering practices. Employer failed to ensure that anchor capacities are verified prior to attaching guywires to the anchors that the verification is less than 24 months old and that the anchor spacing, and capacity is suitable for the mast guying pattern and anticipated loading. structurally designed by a qualified person using accepted engineering practices.
Recent events (2)
- — I (S) $10441.6
- — Z (S) $13052
More inspections at MKS Services LLC
View MKS Services LLC's full OSHA safety record →
More inspections in this industry (NAICS 213111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345953848.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.