PATERSON, NJ —
OSHA Inspection: RAYAN ELECTRIC LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of RAYAN ELECTRIC LLC in 361 MARSHALL ST, PATERSON, NJ 07503 (NAICS 238210). OSHA activity number 345954218.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAYAN ELECTRIC LLC
- Site address
- 361 MARSHALL ST
- City
- PATERSON
- State
- NJ
- ZIP
- 07503
- Mailing
- 197 VALLEY RD, CLIFTON, NJ 07013
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 18
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.403 B02
- Issued
- Oct 19, 2022
- Penalty
- Initial $2,486 · Current $2,486
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Interior - all floors: Employees and other workers were exposed to electric hazards while working around energized equipment including but not limited to loose 4"x4" metal electric boxes with a double receptacle, on or about 4/20/22.
Recent events (1)
- — Z (S) $2486
1926.404 B01 I
- Issued
- Oct 19, 2022
- Penalty
- Initial $3,315 · Current $3,315
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) Interior - all floors: Employees and other workers engaged in construction activities were exposed to electric hazards while powering electric tools on outlets that were not protected by GFCI, on or about 4/20/22.