SAINT LOUIS, MO —
OSHA Inspection: MLK CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MLK CONSTRUCTION LLC in 2006 LAFAYETTE AVE., SAINT LOUIS, MO 63104 (NAICS 236118). OSHA activity number 345956171.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MLK CONSTRUCTION LLC
- Site address
- 2006 LAFAYETTE AVE.
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63104
- Mailing
- 1215 S JEFFERSON AVE, ST. LOUIS, MO 63104, SAINT LOUIS, MO 63104
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Sep 15, 2022
- Penalty
- Initial $4,351 · Current $870 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest systems. On or about May 12, 2022, three employees from MLK Construction LLC were observed working on the rooftop of a split-level residential building located at 2006 Lafayette Ave., St. Louis MO. They were removing/renovating the wall panel of the building. They were not utilizing guardrail system, safety net system, personal fall arrest system nor warning line systems. The three employees were observed on a 4:12 sloped roof, approximately 35 feet above the ground without utilizing fall protection.
Recent events (2)
- — I (S) $870.2
- — Z (S) $4351
1926.1053 B01
- Issued
- Sep 15, 2022
- Penalty
- Initial $4,351 · Current $870 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension was possible because of the ladder's length, the ladder was not secured at its top to a rigid support that would not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about May 12, 2022, three employees from MLK Construction LLC were observed working on the rooftop of a split level residential building located at 2006 Lafayette Ave. in St. Louis MO. They were removing/renovating wall panel of the building wherein workers had to use a 2 extension ladder to access the roof. The ladder was not extended three feet beyond the landing surface or edge of the roof.
Recent events (2)
- — I (S) $870.2
- — Z (S) $4351
1926.1053 B05 I
- Issued
- Sep 15, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). On or about May 12, 2022, three employees from MLK Construction LLC were observed working on the rooftop of a split level residential building located at 2006 Lafayette Ave. in St. Louis MO. They were removing/renovating wall panel of the building wherein workers had to use a 2 extension ladder to access the roof. The ladder did not meet the required angle wherein the horizontal distance from the top to the foot of the ladder was approximately 1:4 ratio of the working length of the ladder.