PATERSON, NJ —
OSHA Inspection: T&L MECHANICAL LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of T&L MECHANICAL LLC in 361 MARSHALL ST, PATERSON, NJ 07503 (NAICS 238220). OSHA activity number 345958375.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- T&L MECHANICAL LLC
- Site address
- 361 MARSHALL ST
- City
- PATERSON
- State
- NJ
- ZIP
- 07503
- Mailing
- 144 BANTA AVE, GARFIELD, NJ 07026
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.300 B01
- Issued
- Oct 19, 2022
- Penalty
- Initial $2,486 · Current $2,486
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) Interior of Building: Employees were exposed to amputation hazards while utilizing a 300 Power Driven Threading Machine without a safety foot switch, on or about 4/20/22.
Recent events (1)
- — Z (S) $2486
1926.403 B02
- Issued
- Oct 19, 2022
- Penalty
- Initial $1,865 · Current $1,865
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Interior - all floors: Employees were exposed to electric hazards while working around energized equipment including but not limited to loose 4"x4" metal electric boxes with a double receptacle, on or about 4/20/22.
Recent events (1)
- — Z (S) $1865
1926.404 B01 I
- Issued
- Oct 19, 2022
- Penalty
- Initial $2,486 · Current $2,486
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) Interior - all floors: Employees engaged in construction activities were exposed to electric hazards while powering electric tools on outlets that were not protected by GFCI, on or about 4/20/22.
Recent events (1)
- — Z (S) $2486
1926.404 F06
- Issued
- Oct 19, 2022
- Penalty
- Initial $1,865 · Current $1,865
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Interior of Building - 2nd Floor: Employees were exposed to electric hazards while utilizing a 300 Power Driven Threading Machine energized by an extension cord without the ground pin, on or about 4/20/22.
Recent events (1)
- — Z (S) $1865
More inspections at T&L Mechanical LLC
View T&L Mechanical LLC's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345958375.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.