On , OSHA opened a complaint safety inspection of AUCTIONZ, LLC in 1520 S SUNCOAST BLVD, HOMOSASSA, FL 34448 (NAICS 424990). OSHA activity number 345962500.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Auctionz, LLC — free Get an email when a new federal OSHA severe-injury report for Auctionz, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
AUCTIONZ, LLC
Site address
1520 S SUNCOAST BLVD
City
HOMOSASSA
State
FL
ZIP
34448
Mailing
1520 S SUNCOAST BLVD, HOMOSASSA, FL 34448
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424990
Employees
14
Ownership type
A

8 citations on file for this inspection.

1910.38 B

Serious Gravity 1 1 instance 14 exposed
Issued
Aug 8, 2022
Penalty
Initial $2,486 · Current $2,486
29 CFR  1910.38(b):An emergency action plan was not in writing, kept in the workplace, and available to employees for review:   a) For the establishment at 1520 S Suncoast Blvd., Homosassa, FL 34448, on or about 05/17/2022, the employer exposed employees to potential burn and inhalation hazards in event of a fire, in that, employees were required to evacuate in event of a fire/emergency and there was no emergency evacuation plan for the establishment.
Recent events (1)
  • — Z (S) $2486

1910.38 D

Serious Gravity 1 1 instance 14 exposed
Issued
Aug 8, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.38(d): The employer did not have and maintain an employee alarm system with a distinctive signal for each purpose so that it complied with the requirements of 1910.165:  a) For the establishment at 1520 S Suncoast Blvd., on or about 05/17/2022, the employer exposed employees to potential burn and inhalation hazards, in that, there was no alarm system in place for employee evacuation of the establishment in event of a fire.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Serious Gravity 1 1 instance 14 exposed
Issued
Aug 8, 2022
Penalty
Initial $2,486 · Current $2,486
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) For warehouse 7, on or about 05/17/2022, the employer exposed employees to potential burn and inhalation hazards, in that, fire extinguishers were blocked by product and inaccessible.
Recent events (1)
  • — Z (S) $2486

1910.157 E03

Serious Gravity 1 1 instance 14 exposed
Issued
Aug 8, 2022
Abate by
Sep 1, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a) For warehouse 7, on or about 05/17/2022, the employer exposed employees to potential burn and inhalation hazards, in that, fire extinguishers were not subjected to a maintenance check annually.
Recent events (1)
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 8, 2022
Abate by
Aug 18, 2022
Penalty
Initial $3,315 · Current $3,315
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.  a) For the electrical cabinet located in warehouse 7 closet, on or about 05/17/2022 and at times prior to, employees were exposed to electrical shock hazards from an unused breaker opening measured to be approximately 1 inch wide.
Recent events (1)
  • — Z (S) $3315

1910.37 B02

Other-than-serious 1 instance 14 exposed
Issued
Aug 8, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(2):Each exit was not clearly visible and marked by a sign reading "Exit":  a) For warehouse 7, as observed on or about 05/17/2022, the employer exposed employees to potential burn and inhalation hazards, in that, exits were missing exit signs.
Recent events (1)
  • — Z (O) $0

1910.37 B06

Other-than-serious 1 instance 14 exposed
Issued
Aug 8, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:   a) For warehouse 7, as observed on or about 05/17/2022, the employer exposed employees to potential burn and inhalation hazards, in that, exits signs were not illuminated.
Recent events (1)
  • — Z (O) $0

1910.178 L06

Other-than-serious 1 instance 14 exposed
Issued
Aug 8, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  a) For warehouse 7, on or about 05/17/2022 and at times prior to, the employer exposed employees to potential struck-by hazards, in that, a certification record of forklift operator's training was not available.
Recent events (1)
  • — Z (O) $0

View Auctionz, LLC's full OSHA safety record →