Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PECO FOODS, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PECO FOODS, INC in 4114 US 67 SOUTH, POCAHONTAS, AR 72455 (NAICS 311615). OSHA activity number 345967392.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Peco Foods, INC — free Get an email when a new federal OSHA severe-injury report for Peco Foods, INC is published. One employer, no account, unsubscribe in one click.
Establishment
PECO FOODS, INC
Site address
4114 US 67 SOUTH
City
POCAHONTAS
State
AR
ZIP
72455
Mailing
4114 HIGHWAY 67 S, POCAHONTAS, AR 72455
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311615
Employees
1216
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Repeat Gravity 10 1 instance 4 exposed
Issued
Sep 30, 2022
Abate by
Oct 20, 2022
Penalty
Initial $79,761 · Current $79,761
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about 5/13/2022, at the  mechanically separated meat (MSM) machine,  authorized employees performing maintenance activities without first utilizing the procedure to deenergize and affix lockout/tagout devices to the machine in the following instances:   a) at the compressed air line ball valve located beneath the Contherm units; b) beneath the Mettler Toledo operating console at the on/off switch.  PECO Foods, Inc.  was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.147(c)(4)(i), which was contained in OSHA inspection number 1527370, citation number 1, item number 1a and was affirmed as a final order on 10/19/2021, with respect to a workplace located at 3701 Reese Phifer Avenue, Tuscaloosa, AL 35401.
Recent events (3)
  • — F (R) $79761
  • — C (R) $79761
  • — Z (R) $79761

1910.147 D02

Repeat Gravity 10 1 instance 4 exposed
Issued
Sep 30, 2022
Abate by
Oct 13, 2022
Penalty
Initial $79,761 · Current $0 Reduced
29 CFR  1910.147(d)(2):  The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:  On or about 5/13/2022, at the directional valve of the mechanically separated meat (MSM) discharge tube.  Employees performed servicing and maintenance activities without first deenergizing the unit.  PECO Foods, Inc.  was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.147(d)(2), which was contained in OSHA inspection number 1285472, citation number 1, item number 3a and was affirmed as a final order on 4/25/2018, with respect to a workplace located at 4114 U.S. Highway 67 South, Pocahontas, Arkansas 72455.
Recent events (3)
  • — F (R) $0
  • — C (R) $79761
  • — Z (R) $79761

1910.147 D04 I

Repeat Gravity 10 4 instances 4 exposed
Issued
Sep 30, 2022
Abate by
Oct 13, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  On or about 5/13/2022, at the mechanical separator, maintenance employees were performing servicing and maintenance at the discharge tube of the separator without affixing lockout/tagout devices at the unit:  a) at the compressed air line ball valve located beneath the Contherm units; b) beneath the Mettler Toledo operating console at the on/off switch.  PECO Foods, Inc.  was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.147(d)(4)(i), which was contained in OSHA inspection number 1285472, citation number 1, item number 3b and was affirmed as a final order on 4/25/2018, with respect to a workplace located at 4114 U.S. Highway 67 South, Pocahontas, Arkansas 72455.
Recent events (3)
  • — F (R) $0
  • — C (R) $0
  • — Z (R) $0

View Peco Foods, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345967392.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.