OSHA Inspection: THE STALWART DEVELOPMENT GROUP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE STALWART DEVELOPMENT GROUP in CASEY AND SMITH TOWERS, SUNY CORTLAND 20 BROADWAY, CORTLAND, NY 13045 (NAICS 562910). OSHA activity number 345971790.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Stalwart Development Group — free Get an email when a new federal OSHA severe-injury report for The Stalwart Development Group is published. One employer, no account, unsubscribe in one click.
Site address
CASEY AND SMITH TOWERS, SUNY CORTLAND 20 BROADWAY
City
CORTLAND
State
NY
ZIP
13045
Mailing
115 AINSLEY DRIVE, SYRACUSE, NY 13210
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
20
Ownership type
A

2 citations on file for this inspection.

1926.502 D11

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 8, 2022
Penalty
Initial $10,151 · Current $7,613 Reduced
29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded:  a) Casey and Smith Towers, SUNY Cortland, 20 Broadway, Cortland, NY  13045, on the 7th floor, on or about 5/11/22:  A worker's lifeline was laying over debris, including the edge of a commercial grade metal stud.
Recent events (2)
  • — I (S) $7613.25
  • — Z (S) $10151

1926.502 D16 III

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 8, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:   a) Casey and Smith Towers, SUNY Cortland, 20 Broadway, Cortland, NY  13045, on the 7th floor, on or about 5/11/22:  A worker's lifeline was laying over debris, including the edge of a commercial grade metal stud and had sufficient slack in the line to ensure a greater than 6-foot free fall.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View The Stalwart Development Group's full OSHA safety record →