Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNDERWATER MECHANIX, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UNDERWATER MECHANIX, LLC in TC DOCK CHARLESTON NAVAL WEAPONS STATION ANNEX, NORTH CHARLESTON, SC 29405 (NAICS 237990). OSHA activity number 345972236.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Underwater Mechanix, LLC — free Get an email when a new federal OSHA severe-injury report for Underwater Mechanix, LLC is published. One employer, no account, unsubscribe in one click.
Site address
TC DOCK CHARLESTON NAVAL WEAPONS STATION ANNEX
City
NORTH CHARLESTON
State
SC
ZIP
29405
Mailing
1004 EASTPORT ROAD, JACKSONVILLE, FL 32218
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237990
Employees
40
Ownership type
A

2 citations on file for this inspection.

1926.405 G02 V

Serious Gravity 5 1 instance 15 exposed
Issued
Jul 15, 2022
Abate by
Jul 19, 2022
Penalty
Initial $4,931 · Current $2,959 Reduced
29 CFR  1926.405(g)(2)(v): Flexible cords and cables were not protected by bushings or fittings where passing through holes in covers, outlet boxes, or similar enclosures.  a) East outer end of the office trailer/container: A 1/2 inch in diameter construction-grade extension cord ran through a 1.5 inch opening at the bottom of a junction box.  There was no bushing or other means to prevent the cord's insulation from making contact with the rough/sharp edge of the opening.  ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (S) $2958.6
  • — Z (S) $4931

1910.1200 E01

Other-than-serious 1 instance 15 exposed
Issued
Jul 15, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Construction Reference: 1926.59) :  a) Worksite: The employer did not  maintain a copy of the hazard communication program that explained the hazards associated with exposure to chemical products such as, but not limited to Denso SeaShield SZ Underwater Epoxy Part A Resin;  Denso SeaShield SZ Underwater Epoxy Part B Hardener; and Euclid Chemical EUCOCRETE.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345972236.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.