Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BAKER INDUSTRIAL FABRICATION, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BAKER INDUSTRIAL FABRICATION, LLC. in 5660 IRIS PARKWAY, FREDERICK, CO 80504 (NAICS 332312). OSHA activity number 345984298.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Baker Industrial Fabrication, LLC. — free Get an email when a new federal OSHA severe-injury report for Baker Industrial Fabrication, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
5660 IRIS PARKWAY
City
FREDERICK
State
CO
ZIP
80504
Mailing
5660 IRIS PARKWAY, FREDERICK, CO 80504
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
22
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 1, 2022
Abate by
Nov 29, 2022
Penalty
Initial $4,144 · Current $3,500 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to struck-by hazards:  a) Baker Industrial Fabrication, LLC, 5660 Iris Pkwy, Frederick, CO 80504: On or about 5/24/2022, the employer did not ensure its employees were protected from the hazards of a compressed gas cylinder tipping over and becoming a projectile in the "Full" cage, located on the east side of the yard.  The cylinders were not secured.  Workers were exposed to struck-by hazards.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4144

1910.184 C12

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 1, 2022
Abate by
Nov 29, 2022
Penalty
Initial $4,972 · Current $4,000 Reduced
29 CFR  1910.184(c)(12): Sling(s) were pulled from under load(s) when load(s) were resting on the sling(s):  (a) Baker Industrial Fabrication, LLC, 5660 Iris Pkwy, Frederick, CO 80504: On or about 5/24/2022, the employer did not ensure that employees were clear of a load that was just staged for paint, prior to the powered industrial truck lifting the sling from the load. The sling caught a piece of the material as it was being lifted, causing the material to roll. This exposed employees to struck by hazards.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4972

1910.303 B02

Other-than-serious Gravity 1 1 instance 8 exposed
Issued
Nov 1, 2022
Abate by
Nov 29, 2022
Penalty
Initial $2,486 · Current $0 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Baker Industrial Fabrication, LLC, 5660 Iris Pkwy, Frederick, CO 80504: On or about 5/24/2022, the employer utilized a relocatable power tap with a UL listing of UL1363 "Relocatable Power Taps", by using it in a series connection with another extension cord. This exposed workers to fire and electrocution hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2486

1910.305 G01 IV A

Other-than-serious Gravity 1 1 instance 8 exposed
Issued
Nov 1, 2022
Abate by
Nov 29, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) Baker Industrial Fabrication, LLC, 5660 Iris Pkwy, Frederick, CO 80504: On or about 5/24/2022, the employer utilized flexible cords as permanent power, running from a 110 generator, for the purpose of powering a hand held mag drill. This exposed workers to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 G01 I C

Other-than-serious Gravity 1 1 instance 8 exposed
Issued
Nov 1, 2022
Abate by
Nov 29, 2022
Penalty
Initial $2,486 · Current $0 Reduced
29 CFR  1910.303(g)(1)(i)(C): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of work space was not clear and did not extend from the grade, floor, or platform to the height required by paragraph (g)(1)(vi) of 29 CFR 1910.303:  a) Baker Industrial Fabrication, LLC, 5660 Iris Pkwy, Frederick, CO 80504: On or about 5/24/2022, the employer did not ensure that the space about the electrical cabinet on the south-east side of the shop was not clear of obstruction to the floor. There were multiple welding leads laying on the floor, just in front of and below the electrical cabinet. This exposed workers to electrical and fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2486

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345984298.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.