On , OSHA opened a complaint safety inspection of STAR PIPE PRODUCTS, LLC in 4018 WESTHOLLOW PARKWAY, HOUSTON, TX 77082 (NAICS 331210). OSHA activity number 345992820.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STAR PIPE PRODUCTS, LLC
- Site address
- 4018 WESTHOLLOW PARKWAY
- City
- HOUSTON
- State
- TX
- ZIP
- 77082
- Mailing
- 4018 WESTHOLLOW PARKWAY, HOUSTON, TX 77082
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331210
- Employees
- 331
- Ownership type
- A
Citations
17 citations on file for this inspection.
1910.133 A01
- Issued
- Nov 22, 2022
- Penalty
- Initial $8,287 · Current $5,387 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On or about May 31, 2022, in the cement area, employees were exposed corrosive material when spraying cement mixture onto pipe fittings without a face shield.
Recent events (2)
- — I (S) $5386.55
- — Z (S) $8287
1910.147 C01
- Issued
- Nov 22, 2022
- Abate by
- Dec 12, 2022
- Penalty
- Initial $10,360 · Current $6,434 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about May 31, 2022 at the facility, an energy control program was not developed and implemented for employees performing servicing and maintenance on equipment such as, but not limited to, the UTL machine (vertical lathe), Carlton radial machine, and The MSDI (multi spindle drill).
Recent events (2)
- — I (S) $6434
- — Z (S) $10360
1910.151 C
- Issued
- Nov 22, 2022
- Penalty
- Initial $8,287 · Current $5,387 Reduced
General-duty citation text
29 CFR 1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) On or about May 31, 2022 in the cement area, an effective eye wash station and/or emergency shower was not provided where employees were spraying cement mix.
Recent events (2)
- — I (S) $5386.55
- — Z (S) $8287
1910.178 L01 II
- Issued
- Nov 22, 2022
- Abate by
- Dec 12, 2022
- Penalty
- Initial $8,287 · Current $5,387 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii):The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck: a) On or about May 31, 2022 at the facility, employees operating forklifts such as, but not limited to, Yale (Model: GLC050VXNDSE085) had not received forklift training.
Recent events (2)
- — I (S) $5386.55
- — Z (S) $8287
1910.303 F02
- Issued
- Nov 22, 2022
- Penalty
- Initial $8,287 · Current $5,387 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) On or about May 31, 2022 in the cement mixing area, a disconnect switch was not marked or identified with its purpose.
Recent events (2)
- — I (S) $5386.55
- — Z (S) $8287
1910.304 F01 IV
- Issued
- Nov 22, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel. a) On or about May 31, 2022, in the cement area, a disconnect switch was obstructed by work tables, a water tank stand and an accumulation of dried cement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 E02
- Issued
- Nov 22, 2022
- Penalty
- Initial $10,360 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(e)(2): Switches, circuit breakers and switchboards installed in wet locations were not enclosed in weatherproof enclosures: a)On or about May 31, 2022 in the cement area, a disconnect switch that was not enclosed was exposed to water from the cement spray.
Recent events (2)
- — I (S) $0
- — Z (S) $10360
1910.305 J02 IV
- Issued
- Nov 22, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location: a) On or about May 31, 2022 in the cement area, an electrical outlet was exposed to water from the cement spray.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 I
- Issued
- Nov 22, 2022
- Penalty
- Initial $8,287 · Current $5,387 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed: a) On or about May 31, 2022, on the cement line, the fitting in between the foot pedals of the work table was not closed, exposing the insulated conductors.
Recent events (2)
- — I (S) $5386.55
- — Z (S) $8287
1910.305 G02 III
- Issued
- Nov 22, 2022
- Penalty
- Initial $8,287 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii):Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) On or about May 31, 2022 in the cement area, a black flexible cord was pulled from the strain relief, exposing the insulated conductor wires.
Recent events (2)
- — I (S) $0
- — Z (S) $8287
1910.334 A02 I
- Issued
- Nov 22, 2022
- Penalty
- Initial $8,287 · Current $0 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) On or about May 31, 2022, in the cement area, the outer insulation of a black extension cord had several cuts, exposing the insulated conductor wires.
Recent events (2)
- — I (S) $0
- — Z (S) $8287
1910.334 A03 I
- Issued
- Nov 22, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor: a) On or about May 31, 2022, a red flexible extension cord used to power equipment such as a fan was missing the grounding prong.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Nov 22, 2022
- Penalty
- Initial $8,287 · Current $5,387 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about May 31, 2022 in the cement area, an electrical box was not equipped with a cover, exposing insulated conductor wires.
Recent events (2)
- — I (S) $5386.55
- — Z (S) $8287
1910.1200 E01
- Issued
- Nov 22, 2022
- Abate by
- Dec 12, 2022
- Penalty
- Initial $12,431 · Current $7,541 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about May 31, 2022, a written hazard communication program was not implemented for employees working with chemicals such as, but not limited to, paint and cement.
Recent events (2)
- — I (S) $7540.9
- — Z (S) $12431
1910.22 A01
- Issued
- Nov 22, 2022
- Penalty
- Initial $6,215 · Current $4,040 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces were kept in a clean, orderly, and sanitary condition: a) On or about May 31, 2022, in the cement area, several items such as extension cords, cement pallets and wooden boards were in an employee walkway.
Recent events (2)
- — I (O) $4039.75
- — Z (S) $6215
1910.212 A01
- Issued
- Nov 22, 2022
- Abate by
- Dec 12, 2022
- Penalty
- Initial $10,360 · Current $6,434 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about May 31, 2022, in the production area, the rotating piece being milled by the vertical lathe was not guarded, exposing employees to caught-in hazards.
Recent events (2)
- — I (O) $6434
- — Z (S) $10360
1910.303 G02 I
- Issued
- Nov 22, 2022
- Penalty
- Initial $8,287 · Current $5,387 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) On or about May 31, 2022 in the office area, an outlet used to power an air purification unit did not have a faceplate.
Recent events (2)
- — I (O) $5386.55
- — Z (S) $8287
More inspections at Star Pipe Products, LLC
View Star Pipe Products, LLC's full OSHA safety record →
More inspections in this industry (NAICS 331210)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345992820.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.