OSHA Inspection: ACEVEDO PLUMBING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ACEVEDO PLUMBING in 6510 ROHAN RD, RICHMOND, TX 77469 (NAICS 238220). OSHA activity number 345995955.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Acevedo Plumbing — free Get an email when a new federal OSHA severe-injury report for Acevedo Plumbing is published. One employer, no account, unsubscribe in one click.
Establishment
ACEVEDO PLUMBING
Site address
6510 ROHAN RD
City
RICHMOND
State
TX
ZIP
77469
Mailing
25720 PEACH CREEK DR., NEW CANEY, TX 77357
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 21, 2022
Abate by
Jul 18, 2022
Penalty
Initial $3,108 · Current $1,862 Reduced
29 CFR  1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person (i.e., a person who is capable of identifying exist):  a) At this jobsite, a competent person did not perform frequent and regular inspections of the jobsites, materials, and equipment, exposing employees to engulfment hazards.
Recent events (2)
  • — I (S) $1862
  • — Z (S) $3108

1926.651 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 21, 2022
Abate by
Jun 27, 2022
Penalty
Initial $3,108 · Current $1,864 Reduced
29 CFR  1926.651(c)(2):  A stairway, ladder, ramp or other safe means of egress was not located in the trench excavation that was 4 feet or more in depth for employees to egress when required:  a) At this jobsite, a ladder was not located in an approximately 40 feet long, 5-feet wide, and 9-feet deep excavation, exposing the employee inside the excavation to caught-in hazards.
Recent events (2)
  • — I (S) $1864
  • — Z (S) $3108

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 21, 2022
Abate by
Jun 27, 2022
Penalty
Initial $4,351 · Current $2,610 Reduced
29 CFR  1926.652(a)(1):  Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:  a) At this jobsite, an approximately 40-feet long, 5-feet wide, and 9-feet deep excavation had no protective system, exposing employees to caught-in hazards.
Recent events (2)