Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SF REMODELING CONSTRUCTION LLP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SF REMODELING CONSTRUCTION LLP in 1419 NORTH CAMERON STREET BUILDING A7, HARRISBURG, PA 17103 (NAICS 238160). OSHA activity number 345997621.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SF Remodeling Construction LLP — free Get an email when a new federal OSHA severe-injury report for SF Remodeling Construction LLP is published. One employer, no account, unsubscribe in one click.
Site address
1419 NORTH CAMERON STREET BUILDING A7
City
HARRISBURG
State
PA
ZIP
17103
Mailing
8199 OAKLAND ROAD, MANASSAS, VA 20110
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 8 exposed
Issued
Sep 26, 2022
Abate by
Oct 14, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR  1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):   (a) 1419 North Cameron Street Harrisburg, PA, Building A7, Porch roof  - On or about May 18, 2022, employees were tearing off and installing a residential roof with a roof slope greater than 4 in 12 pitch with the height of approximately 10 feet above grade without  fall protection.  (a) 1419 North Cameron Street Harrisburg, PA, Building A7 - On or about May 18, 2022, employees were tearing off and installing a residential roof with a roof slope greater than 4 in 12 pitch with the height of approximately 15 feet above grade without  fall protection.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $4351

1926.1053 B01

Serious Gravity 5 2 instances 8 exposed
Issued
Sep 26, 2022
Abate by
Oct 14, 2022
Penalty
Initial $2,486 · Current $2,486
29 CFR  1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.   (a) 1419 North Cameron Street Harrisburg, PA, Building A7 - On or about May 18, 2022, the portable extension ladders that accessed the 2nd story sub-roof did not extend 3 feet above the landing surfaces at the front of the residential building where the front porches were.   (b) 1419 North Cameron Street Harrisburg, PA, Building A7 - On or about May 18, 2022, the portable extension ladders that accessed the 3rd story main roof did not extend 3 feet above the landing surfaces at the front of the residential building where the front porches were.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $2486

View SF Remodeling Construction LLP's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345997621.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.