SAEGERTOWN, PA —
OSHA Inspection: ADLER INDUSTRIAL SOLUTIONS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ADLER INDUSTRIAL SOLUTIONS, INC. in 18927 RESERVOIR ROAD, SAEGERTOWN, PA 16433 (NAICS 333511). OSHA activity number 345998561.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADLER INDUSTRIAL SOLUTIONS, INC.
- Site address
- 18927 RESERVOIR ROAD
- City
- SAEGERTOWN
- State
- PA
- ZIP
- 16433
- Mailing
- 18927 RESERVOIR ROAD, SAEGERTOWN, PA 16433
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333511
- Employees
- 21
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.303 B02
- Issued
- Jul 18, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $2,113 · Current $1,479 Reduced
General-duty citation text
29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a.) Adler Tooling Solutions, Inc. dba Pinnacle Molds - On or about 6/2/22, and at times prior thereto, a Relocatable Power Tab (aka Multioutlet Surge Protector) was being used to power equipment including, but not limited to, a vertical band saw. The Relocatable Power Tab was not listed and labeled for industrial environments. The Relocatable Power Tap was listed/designed for household use. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1479.1
- — Z (S) $2113