CLAREMONT, NH —
OSHA Inspection: MATRIX AEROSPACE CORP.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MATRIX AEROSPACE CORP. in 423 RIVER ROAD, CLAREMONT, NH 03743 (NAICS 332999). OSHA activity number 345998835.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MATRIX AEROSPACE CORP.
- Site address
- 423 RIVER ROAD
- City
- CLAREMONT
- State
- NH
- ZIP
- 03743
- Mailing
- 421 RIVER ROAD, CLAREMONT, NH 03743
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 81
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 29, 2022
- Abate by
- Aug 10, 2022
- Penalty
- Initial $6,527 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a.) Baldor Buffer, beside CNC machines - On or about June 3, 2022, the arbor nuts and shaft ends of the Baldor buffer were not guarded to protect the operators from rotating parts. b.) Baldor Buffer, front of Milling machines - On or about June 3, 2022, the arbor nuts and shaft ends of the Baldor buffer were not guarded to protect the operators from rotating parts. c.) Baldor Buffer, beside Milling machines - On or about June 3, 2022, the arbor nuts and shaft ends of the Baldor buffer were not guarded to protect the operators from rotating parts.
Recent events (2)
- — I (S) $3000
- — Z (S) $6527
1910.303 B02
- Issued
- Jul 29, 2022
- Penalty
- Initial $6,527 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: CNC production area of building 423 - On or about June 3, 2022, A Belkin relocatable power tap was in use under a table, which was plugged into an extension cord. Listing and labeling states that relocatable power taps are to be directly connected to a permanently installed branch circuit receptacle.
Recent events (2)
- — I (S) $0
- — Z (S) $6527
1910.303 E01 II
- Issued
- Jul 29, 2022
- Abate by
- Aug 10, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Electric equipment was used without markings giving voltage, current, wattage, or other ratings as necessary. New Building, 423 River Rd. - On or about June 3, 2022, Circuit breaker panels and floor mounted electrical transformers were in use and did not have markings or labeling to identify the voltage or other ratings they contained.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Matrix Aerospace Corp.
View Matrix Aerospace Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345998835.