Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M Q EXTERIORS CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of M Q EXTERIORS CONSTRUCTION, LLC in 1304-1303 CHURCHILL CIRCLE FOX HOLLOW AT BRANCHBURG, BLDG 13, BRANCHBURG, NJ 08853 (NAICS 238170). OSHA activity number 346001258.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M Q Exteriors Construction, LLC — free Get an email when a new federal OSHA severe-injury report for M Q Exteriors Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1304-1303 CHURCHILL CIRCLE FOX HOLLOW AT BRANCHBURG, BLDG 13
City
BRANCHBURG
State
NJ
ZIP
08853
Mailing
115 MARSHALL ST., #1, ELIZABETH, NJ 07206
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.451 G04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 24, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR  1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:  a. 3456 US-22 W., Branchburg, NJ - Fox Hollow at Branchburg - Building 13  The employer did not ensure that pump jack scaffolds were protected along all open sides.  Employees engaged in residential siding activities use Alum-a-pole pump jack scaffold that did not have end rails installed or fall protection netting secured prior to releasing the scaffold for use.   Violation observed on or about June 6, 2022
Recent events (1)
  • — Z (S) $4351

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 24, 2022
Penalty
Initial $2,486 · Current $2,486
29 CFR  1926.452(j)(2):Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.  a. 3456 US-22 W., Branchburg, NJ - Fox Hollow at Branchburg - Building 13  The employer did not ensure bottom bracing was installed on the pump jack scaffolds.  Employees engaged in residential siding activities worked  from Alum-A-Pole pump jack scaffolds that were not fully braced at the bottoms, which would ensure scaffold stability from kick out as the scaffold platforms were adjusted to elevation.   Violation observed on or about June 6, 2022
Recent events (1)
  • — Z (S) $2486

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346001258.