OSHA Inspection: N.A.L. COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of N.A.L. COMPANY, INC. in 112 MILLS ST., MOUNT ORAB, OH 45154 (NAICS 322220). OSHA activity number 346009079.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch N.A.L. Company, INC. — free Get an email when a new federal OSHA severe-injury report for N.A.L. Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
112 MILLS ST.
City
MOUNT ORAB
State
OH
ZIP
45154
Mailing
112 MILLS ST., MOUNT ORAB, OH 45154
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322220
Employees
34
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Jun 29, 2022
Abate by
Aug 4, 2022
Penalty
Initial $10,151 · Current $0 Reduced
29 CFR  1910.147(c)(1):Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  a) On or about June 6, 2022, the employer did not have an energy control program that included specific energy isolation procedures, training for authorized, affected, and other employees, and periodic inspections of the procedures on an annual basis for equipment such as but not limited to; the 70" and 90" Winder Machines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10151

1910.147 D

Deleted Serious Gravity 10 2 instances 6 exposed
Issued
Jun 29, 2022
Abate by
Aug 4, 2022
Penalty
Initial $10,151 · Current $0 Reduced
29 CFR  1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:   Each employee was not required to: (1) turn off and shut down the machines, (2) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the electric and pneumatic energy sources, (3) affix lockout or tagout devices to each energy-isolating device, (4) verify the effectiveness of energy isolation.  a) On or about  June 6, 2022, on the 70" Winder Machine, each operators performing set up activities did not lock out the machine when performing tasks such as paper roll changes.  b) On or about May 6, 2022, on the 70" and 90" Winder Machines, each operator performing servicing operations did not lock out the machine when performing tasks such as bearing changes.