Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. AIR FORCE - BEALE AFB, CIVIL ENGINEERING SQUADRON

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. AIR FORCE - BEALE AFB, CIVIL ENGINEERING SQUADRON in 17851 16TH STREET, BEALE AFB, CA 95903 (NAICS 928110). OSHA activity number 346011612.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. AIR Force - Beale AFB, Civil Engineering Squadron — free Get an email when a new federal OSHA severe-injury report for U.S. AIR Force - Beale AFB, Civil Engineering Squadron is published. One employer, no account, unsubscribe in one click.
Site address
17851 16TH STREET
City
BEALE AFB
State
CA
ZIP
95903
Mailing
17851 16TH STREET, BEALE AFB, CA 95903
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
879
Ownership type
D

4 citations on file for this inspection.

1910.37 A01

Serious Gravity 5 1 instance 12 exposed
Issued
Aug 11, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(1): Exit routes shall not have flammable, explosive, combustible gases or flammable furnishings stored in the exit route.  Building 25390, Sheet Metal Shop: Acetylene cylinder was stored near a designated exit.
Recent events (1)
  • — Z (S) $0

1910.213 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 11, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  Building 25390, Wood Shop: The 10 inch Delta (Unisaw #14C000071) table saw used for ripping purposes, was not provided with a blade guard that adjust to the thickness of the materials being cut and remain in contact with it. Employees were exposed to amputation related injuries.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 11, 2022
Abate by
Sep 1, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to the joints or terminal screws:  Building 25390, Welding Shop: The DEWALT (DW 402, SER 941204) right angle hand grinder power supply cord lacked strain relief from both ends. The power supply cord was missing approximately half an inch of its outer sheathing on its plug end exposing the inner conductors to physical damage. Employees were exposed to electrical hazards.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Repeat Gravity 5 1 instance 2 exposed
Issued
Aug 11, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Building 25390, Welding Shop: The BAILEIGH horizontal saw (Serial Number 17A01017) was not provided with a guard to protect the unused portion of the saw. Employees were exposed to amputation related injuries.  The U.S. AIR FORCE - BEALE AFB, Civil Engineering Squadron was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1232826, citation number 02, item number 01 and was affirmed as a final order on  08/31/2017, with respect to a workplace located at 17851 16th Street, Beale AFB, CA 95903
Recent events (1)
  • — Z (R) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346011612.