MEDFORD, WI —
OSHA Inspection: WEATHER SHIELD MFG., INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WEATHER SHIELD MFG., INC. in 642 SOUTH WHELEN AVENUE, MEDFORD, WI 54451 (NAICS 321911). OSHA activity number 346013154.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WEATHER SHIELD MFG., INC.
- Site address
- 642 SOUTH WHELEN AVENUE
- City
- MEDFORD
- State
- WI
- ZIP
- 54451
- Mailing
- P.O. BOX 309, MEDFORD, WI 54451
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321911
- Employees
- 240
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 D02
- Issued
- Aug 31, 2022
- Abate by
- Sep 15, 2022
- Penalty
- Initial $7,748 · Current $3,874 Reduced
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) Electronic department; The written energy isolation procedures for isolating and affixing lockout devices were not utilized before cleaning activities were performed on a Black Brothers glue roller, Equipment #M0329.
Recent events (2)
- — I (S) $3874
- — Z (S) $7748
1910.213 A09
- Issued
- Aug 31, 2022
- Abate by
- Sep 15, 2022
- Penalty
- Initial $5,811 · Current $2,906 Reduced
General-duty citation text
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requirements of 1910.219: (a) Electronic department; A sprocket that guides a drive chain for a mechanically driven ram was not guarded on the Rosenquist, Inc. electronic glue machine, model #50KWGEN, serial #206RB131251-50K.
Recent events (2)
- — I (S) $2905.5
- — Z (S) $5811
1910.213 R01
- Issued
- Aug 31, 2022
- Abate by
- Sep 15, 2022
- Penalty
- Initial $7,748 · Current $3,874 Reduced
General-duty citation text
29 CFR 1910.213(r)(1): Feed rolls of roll type glue spreader(s) were not guarded by a semicylindrical guard: (a) Electronic department; The Black Brothers glue roller, equipment #M0329, did not have adequate guarding to prevent employees from accessing the ingoing nip point created by the glue roll in-feed.
Recent events (2)
- — I (S) $3874
- — Z (S) $7748
1910.213 R04
- Issued
- Aug 31, 2022
- Abate by
- Sep 15, 2022
- Penalty
- Initial $14,502 · Current $7,251 Reduced
General-duty citation text
29 CFR 1910.213(r)(4): Suitable guard(s) were not provided to reduce to a minimum the hazard due to the point of operation of an electronic glue machine: (a) Electronic Department; At approximately 8:00 a.m., on or about May 31, 2022, an electronic department employee suffered an amputation injury while removing a press block from an inadequately guarded Rosenquist, Inc. electronic glue machine, model #50KWGEN, serial #206RB131251-50K. The employee's thumb was caught between the press block and the metal guiderail when a chain driven ram was activated and pushed the next set of door stiles on the glue machine line forward.
Recent events (2)
- — I (S) $7251
- — Z (S) $14502
1910.147 C05 II
- Issued
- Aug 31, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not used for lockout and tagout purposes only: (a) Electronic Department; A lockout lock was improperly used to keep a rolling table stationary during normal operation of the Rosenquist, Inc. electronic glue machine, model #50KWGEN, serial #206RB131251-50K.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Weather Shield MFG., INC.
View Weather Shield MFG., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321911)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346013154.