BONITA SPRINGS, FL —
OSHA Inspection: 1ST CHOICE HURRICANE PROTECTION LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of 1ST CHOICE HURRICANE PROTECTION LLC in 27086 SHELL RIDGE CIRCLE, BONITA SPRINGS, FL 34133 (NAICS 238150). OSHA activity number 346014038.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 1ST CHOICE HURRICANE PROTECTION LLC
- Site address
- 27086 SHELL RIDGE CIRCLE
- City
- BONITA SPRINGS
- State
- FL
- ZIP
- 34133
- Mailing
- 25241 BERNWOOD DR SUITE 6, BONITA SPRINGS, FL 34135
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238150
- Employees
- 28
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Jul 15, 2022
- Abate by
- Aug 10, 2022
- Penalty
- Initial $10,151 · Current $5,076 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than 1 inch wide: a. On or about June 08, 2022, employees were installing windows on a two-story single-family home from a 2-tier supported scaffold, during which time the working level of the scaffold was not fully planked or decked such that the space between adjacent units, and the space between the platform and the uprights was more than 1 inch wide; therefore exposing the employees to a 14'-9" fall hazard.
Recent events (2)
- — I (S) $5075.5
- — Z (S) $10151
1926.451 F07
- Issued
- Jul 15, 2022
- Abate by
- Aug 10, 2022
- Penalty
- Initial $10,151 · Current $5,076 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a. On or about June 08, 2022, employees were installing windows on a two-story single-family home from a 2-tier supported scaffold, during which time the scaffold and scaffold components had not been erected, moved, dismantled and altered by trained and experienced employees, nor while under the supervision and direction of a scaffolding competent person nor while under the supervision and direction of a scaffolding qualified person, and wherein the scaffold system was found to contain several visible predictable hazards such as having not been fully planked and having been missing the guardrails; therefore exposing the employees to a 14'-9" fall hazard.
Recent events (2)
- — I (S) $5075.5
- — Z (S) $10151
1926.20 B02
- Issued
- Jul 15, 2022
- Abate by
- Aug 10, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a. On or about June 08, 2022, employees were installing windows on a two-story single-family home from a 2-tier supported scaffold, during which time the scaffold and scaffold components had not been inspected by a competent person prior to use, and wherein the scaffold system was found to contain several visible predictable hazards such as having not been fully planked and having been missing the guardrails; therefore exposing the employees to a 14'-9" fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Jul 15, 2022
- Abate by
- Aug 10, 2022
- Penalty
- Initial $10,151 · Current $5,076 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about June 08, 2022, employees were installing windows on a two-story single-family home from a 2-tier supported scaffold, during which time the employees were not using a Personal Fall Arrest System nor was the three open sides of the working level of the scaffold protected with a guardrail system; therefore exposing the employees to a 14'-9" fall hazard.
Recent events (2)
- — I (S) $5075.5
- — Z (S) $10151
More inspections in this industry (NAICS 238150)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346014038.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.