WOBURN, MA —
OSHA Inspection: RELIABLE FENCE COMPANY OF THE NORTH SHORE, INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of RELIABLE FENCE COMPANY OF THE NORTH SHORE, INC in 283 SALEM STREET, WOBURN, MA 01801 (NAICS 423390). OSHA activity number 346015084.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RELIABLE FENCE COMPANY OF THE NORTH SHORE, INC
- Site address
- 283 SALEM STREET
- City
- WOBURN
- State
- MA
- ZIP
- 01801
- Mailing
- 283 SALEM STREET, WOBURN, MA 01801
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423390
- Employees
- 50
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.303 E01 II
- Issued
- Oct 12, 2022
- Penalty
- Initial $5,801 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.303(e)(1)(ii): 1910.303(e)(1)(ii) Electrical equipment were not marked giving voltage, current, wattage or other ratings as necessary: Location: Compressor Room On or about 6/13/2022, two (2) live electrical panels were not marked with voltage ratings.
Recent events (2)
- — I (S) $2300
- — Z (S) $5801
1910.303 G01
- Issued
- Oct 12, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. Location: Yard On or about 6/13/2022, a live electrical panel was obstructed by stored materials including wood, debris, and materials.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Oct 12, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: Location: Yard A) On or about 6/13/2022, the cover of the live electrical panel cover was damaged. Location: Compressor Room B) On or about 6/13/2022, the cover of a live electrical panel was left open.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Oct 12, 2022
- Abate by
- Mar 31, 2023
- Penalty
- Initial $4,351 · Current $2,200 Reduced
General-duty citation text
29 CFR 1910.134(c)(1):A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use. Location: Shop On or about 6/13/22, a written respirator program was not developed and implemented for welding jobs requiring P100 tight fitting elastomeric half face respirator use.
Recent events (2)
- — I (S) $2200
- — Z (S) $4351
1910.134 D01 III
- Issued
- Oct 12, 2022
- Abate by
- Mar 31, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(iii):The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form. Location: Shop On or about 6/13/2022, the employer did not identify and evaluate respiratory hazards including welding fumes.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Oct 12, 2022
- Abate by
- Mar 31, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION/CONDITION) (DESCRIBE HAZARD). Location: Facility On or about 6/13/2022, an employee directed to utilize a Miller P100 tight-fitting half face elastomeric respirator was not provided a medical evaluation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Oct 12, 2022
- Abate by
- Mar 31, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1):The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT). Location: Shop On or about 6/13/2022, an employee directed to don a Miller P100 tight fitting face piece respirator was not provided a fit test.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 423390)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346015084.