Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUASAR ENERGY GROUP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of QUASAR ENERGY GROUP in 2072 SECREST ROAD, WOOSTER, OH 44691 (NAICS 221118). OSHA activity number 346022627.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quasar Energy Group — free Get an email when a new federal OSHA severe-injury report for Quasar Energy Group is published. One employer, no account, unsubscribe in one click.
Establishment
QUASAR ENERGY GROUP
Site address
2072 SECREST ROAD
City
WOOSTER
State
OH
ZIP
44691
Mailing
8600 EAST PLEASANT VALLEY ROAD, INDEPENDENCE, OH 44131
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221118
Employees
2
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 5, 2022
Abate by
Jan 24, 2023
Penalty
Initial $10,151 · Current $7,613 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a flash fire hazard from the uncontrolled release of flammable digester gas:   On or about June 14, 2022, the digestion tank, used in the process of digesting flammable gases (methane and biogas) from organic liquid substrate, presented a flash fire hazard related to the uncontrolled release of flammable gas from the vessel originating from excessive internal pressures developed during unplanned shutdown conditions.
Recent events (2)
  • — I (S) $7613
  • — Z (S) $10151

1910.120 Q01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 5, 2022
Abate by
Jan 24, 2023
Penalty
Initial $10,151 · Current $0 Reduced
29 CFR  1910.120(q)(1): The employer did not develop and implement an emergency response plan to handle anticipated emergencies prior to commencement of emergency response operations:  On or about June 14, 2022, the employer failed to develop and implement an emergency response plan. There was a rupture of the roofing membrane on the Digester Tank after a power-outage caused the digesters/agitators to stop mixing effluent, resulting in a build-up of effluent-foam and methane within the tank and a subsequent rupture and flash fire due to methane release on June 14, 2022, which resulted in injured and hospitalized workers. The workers were completing emergency response tasks at the time of the rupture and flash fire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10151

1910.120 Q06

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 5, 2022
Abate by
Jan 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.120(q)(6):The skill and knowledge levels required for all new responders, and those hired after the effective date of this standard, were not conveyed to them through training before they were permitted to take part in actual emergency operations on an incident:  On or about June 14, 2022, the employer failed to develop and implement an emergency response plan that included adequate training. There was a rupture of the roofing membrane on the Digester Tank after a power-outage caused the digesters/agitators to stop mixing effluent, resulting in a build-up of effluent-foam and methane within the tank and a subsequent rupture and flash fire due to methane release on June 14, 2022, which resulted in injured and hospitalized workers. The workers were completing emergency response tasks at the time of the rupture and flash fire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.307 C

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 5, 2022
Abate by
Jan 24, 2023
Penalty
Initial $10,151 · Current $7,613 Reduced
29 CFR  1910.307(c):Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:  On or about June 14, 2022, the employer failed to ensure that the motors/agitators for the mixers on the Digestion Tank were rated for hazardous atmospheres, class 1 division 1, locations.
Recent events (2)
  • — I (S) $7613
  • — Z (S) $10151

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346022627.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.