Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ABM ELECTRIC, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ABM ELECTRIC, LLC in 16 W FREEDOM WAY, CINCINNATI, OH 45202 (NAICS 238210). OSHA activity number 346022668.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ABM Electric, LLC — free Get an email when a new federal OSHA severe-injury report for ABM Electric, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ABM ELECTRIC, LLC
Site address
16 W FREEDOM WAY
City
CINCINNATI
State
OH
ZIP
45202
Mailing
7710 READING ROAD SUITE 003, CINCINNATI, OH 45237
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 25, 2022
Abate by
Nov 7, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR  1926.20(b)(2): Accident prevention responsibilities. Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  a) On or about June 14, 2022, the employer did not ensure that a frequent and regular inspection program was being maintained in use by a competent person to ensure that job site, material and equipment; such as but not limited to personal protective equipment that is appropriate for working energized on equipment such as the 480v energized circuit that was being moved.
Recent events (1)
  • — Z (S) $4351

1926.95 A

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 25, 2022
Abate by
Nov 7, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR  1926.95(a): Personal Protective and Life Saving Equipment. Criteria for personal protective equipment. "Application." Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.  a) On or about June 14, 2022, the employer did not ensure that employees working for a new commercial tenant The Frost Factory did not used electrical protective equipment that is appropriate to protect employees from exposure to electrical burns on the arms and face from an energized electrical source of 480v.
Recent events (1)
  • — Z (S) $4351

1926.416 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 25, 2022
Abate by
Nov 7, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR  1926.416(a)(1): General requirement. Protection of employees. No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.  a) On or about June 14, 2022, the employer did not ensure that employees working in the electric room for The Frost Factory a new retail tenant at a commercial building were not exposed to electrical shock when working with the 480v energized circuit that was being moved by ensuring that the circuit had been de-energized prior to moving.
Recent events (1)
  • — Z (S) $4351

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346022668.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.