OSHKOSH, WI —
OSHA Inspection: GENERAC POWER SYSTEMS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GENERAC POWER SYSTEMS, INC. in 3815 OREGON STREET, OSHKOSH, WI 54902 (NAICS 335312). OSHA activity number 346034077.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENERAC POWER SYSTEMS, INC.
- Site address
- 3815 OREGON STREET
- City
- OSHKOSH
- State
- WI
- ZIP
- 54902
- Mailing
- 3815 OREGON STREET, OSHKOSH, WI 54902
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335312
- Employees
- 275
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.151 C
- Issued
- Aug 26, 2022
- Abate by
- Sep 26, 2022
- Penalty
- Initial $8,806 · Current $6,164 Reduced
General-duty citation text
29 CFR 1910.151(c):Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. On or about June 22, 2022, employees who performs daily inspections on the forklifts which include checking battery levels was not provided with an eyewash station within the charging area known as the satellite charging station. A suitable facility for quick drenching or flushing of the eyes were not provided within the work area for immediate emergency use while employees are checking levels for Lead Acid Batteries that contains Sulfuric Acid, thus exposing employees to potential chemical burn hazard to the eyes.
Recent events (2)
- — I (S) $6164
- — Z (S) $8806
More inspections at Generac Power Systems, INC.
View Generac Power Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 335312)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346034077.