OSHA Inspection: PARKER TRUTEC, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of PARKER TRUTEC, INC. in 4700 GATEWAY BOULEVARD, SPRINGFIELD, OH 45503 (NAICS 332811). OSHA activity number 346034085.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PARKER TRUTEC, INC.
- Site address
- 4700 GATEWAY BOULEVARD
- City
- SPRINGFIELD
- State
- OH
- ZIP
- 45503
- Mailing
- 4700 GATEWAY BOULEVARD, SPRINGFIELD, OH 45503
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332811
- Employees
- 157
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.146 D03 IV
- Issued
- Oct 13, 2022
- Abate by
- Nov 2, 2022
- Penalty
- Initial $14,502 · Current $8,701 Reduced
General-duty citation text
Permit-required confined space program (permit space program). Under the permit space program required by paragraph (c)(4) of this section, the employer shall: 29 CFR 1910.146(d)(3)(iv): Purging, inerting, flushing, or ventilating the permit space as necessary to eliminate or control atmospheric hazards; a.) On or about June 7, 2022, the employer did not ventilate the permit required confined space Furnace SC7 to eliminate atmospheric hazards prior to entry in that nitrogen was leaking into the space when employees entered the permit required confined space.
Recent events (2)
- — I (S) $8701.2
- — Z (S) $14502
1910.146 D03 VI
- Issued
- Oct 13, 2022
- Abate by
- Nov 2, 2022
- Penalty
- Initial $14,502 · Current $8,701 Reduced
General-duty citation text
Permit-required confined space program (permit space program). Under the permit space program required by paragraph (c)(4) of this section, the employer shall: 29 CFR 1910.146(d)(3)(vi): Verifying that conditions in the permit space are acceptable for entry throughout the duration of an authorized entry. a.) On or about June 7, 2022, the employer did not verify the atmospheric conditions in Furnace SC7 throughout the duration of the authorized entry in that, atmospheric testing was not conducted at the main furnace chamber door where the employees were working.
Recent events (2)
- — I (S) $8701.2
- — Z (S) $14502
1910.146 D05 I
- Issued
- Oct 13, 2022
- Abate by
- Nov 2, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(5)(i): Test conditions in the permit space to determine if acceptable entry conditions exist before entry is authorized to begin, except that, if isolation of the space is infeasible because the space is large or is part of a continuous system (such as a sewer), pre-entry testing shall be performed to the extent feasible before entry is authorized and, if entry is authorized, entry conditions shall be continuously monitored in the areas where authorized entrants are working; a.) On or about June 7, 2022, the employer did not determine if acceptable entry conditions existed and were continuously monitored in Furnace SC7 in that, atmospheric monitoring was not conducted where employees were working at the main furnace chamber door.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 K03 II
- Issued
- Oct 13, 2022
- Abate by
- Nov 2, 2022
- Penalty
- Initial $14,502 · Current $8,701 Reduced
General-duty citation text
To facilitate non-entry rescue, retrieval systems or methods shall be used whenever an authorized entrant enters a permit space, unless the retrieval equipment would increase the overall risk of entry or would not contribute to the rescue of the entrant. Retrieval systems shall meet the following requirements: 29 CFR 1910.146(k)(3)(ii): The other end of the retrieval line shall be attached to a mechanical device or fixed point outside the permit space in such a manner that rescue can begin as soon as the rescuer becomes aware that rescue is necessary. A mechanical device shall be available to retrieve personnel from vertical type permit spaces more than 5 feet (1.52 m) deep. a.) On or about June 7, 2022, the employer did not provide and use a mechanical device or fixed point outside Furnace SC7 to attach the retrieval line and employee #1 entered the space to rescue employee #2 by grabbing his harness or lanyard.
Recent events (2)
- — I (S) $8701.2
- — Z (S) $14502
1910.146 F03
- Issued
- Oct 13, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(f)(3): The date and the authorized duration of the entry permit; a.) On or about June 7, 2022, the employer's confine space entry permit did not include the authorized duration of the entry permit.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Parker Trutec, INC.
View Parker Trutec, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332811)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346034085.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.