Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MASTERCRAFTERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MASTERCRAFTERS, INC. in 1234 SOUTH GOVERNORS AVENUE, DOVER, DE 19904 (NAICS 337110). OSHA activity number 346037526.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mastercrafters, INC. — free Get an email when a new federal OSHA severe-injury report for Mastercrafters, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1234 SOUTH GOVERNORS AVENUE
City
DOVER
State
DE
ZIP
19904
Mailing
1234 SOUTH GOVERNORS AVENUE, DOVER, DE 19904
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
337110
Employees
20
Ownership type
A

23 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $4,972 · Current $3,232 Reduced
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.  a) 1234 South Governors Avenue, Dover DE 19904: On or about June 23, 2022, the site was cluttered by cardboard boxes, trash, cabinet building materials, paperwork, ladders, and other miscellaneous items.
Recent events (3)
  • — C (S) $4972
  • — F (S) $3231.8
  • — Z (S) $4972

1910.36 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $4,972 · Current $3,232 Reduced
29 CFR 1910.36(b)(1): Two exit routes. At least two exit routes were not available in the workplace to permit prompt evacuation of employees and other building occupants during an emergency, except as allowed in paragraph (b)(3) of this section. The exit routes must be located as far away as practical from each other so that if one exit route is blocked by fire or smoke, employees can evacuate using the second exit route:   a) 1234 South Governors Avenue, Dover, DE 19904: On or about June 23, 2022,  employees working in the warehouse area on the southern side had only one exit route, through the warehouse, exposing these employees to injuries during an emergency evacuation.
Recent events (3)
  • — C (S) $4972
  • — F (S) $3231.8
  • — Z (S) $4972

1910.37 A02

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $4,972 · Current $3,232 Reduced
29 CFR 1910.37(a)(2): Exit routes must be arranged so that employees will not have to travel toward a high hazard area, unless the path of travel is effectively shielded from the high hazard area by suitable partitions or other physical barriers.  a) 1234 South Governors Avenue, Dover, DE 19904 (Shop Areas and Paint area): On or about June 23, 2022, exit routes obstructed by a 5-gallon flammable container of Wilsonart 1700 contact adhesive stored along the exit egress route, along with various other flammable liquids stored outside a exit door. Additionally, the walking working surfaces were covered with wood dust determined to be explosive which was located along the route.
Recent events (3)
  • — C (S) $4972
  • — F (S) $3231.8
  • — Z (S) $4972

1910.37 A03

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3):Exit route(s) were not kept free and unobstructed:  a) 1234 South Governors Avenue, Dover, DE 19904 (Warehouse): On or about June 23, 2022, exit routes in the warehouse were blocked by completed cabinets stacked in an unorganized fashion.   b) 1234 South Governors Avenue, Dover, DE 19904 (Corian shop): On or about June 23, 2022, exit routes in the Corian shop were blocked by cabinet materials stacked in an unorganized fashion.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.37 B01

Serious Gravity 10 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(1): Each exit route must be adequately lighted so that an employee with normal vision can see along the exit route.  a) 1234 South Governors Avenue, Dover, DE 19904: On or about June 23, 2022, exit routes were not lit and operations extended into the hours of darkness.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.37 B02

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  a) 1234 South Governors Avenue, Dover, DE 19904: On or about June 23, 2022, emergency exits were not visible or marked with an "exit" sign as required.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.37 B04

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:   a) 1234 South Governors Avenue, Dover, DE 19904: On or about June 23, 2022, signs were not posted indicating the direction of travel to the nearest exit access.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.38 D

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $2,486 · Current $1,616 Reduced
29 CFR 1910.38(d): Employee alarm system. An employer must have and maintain an employee alarm system. The employee alarm system must use a distinctive signal for each purpose and comply with the requirements in �� 1910.165.  a) 1234 South Governors Avenue, Dover, DE 19904: On or about June 23, 2022, the building was not provided with an alarm, paging system or other method to alert employees to evacuate in the event of an emergency.
Recent events (3)
  • — C (S) $2486
  • — F (S) $1615.9
  • — Z (S) $2486

1910.38 E

Serious Gravity 10 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.38(e): Training. An employer must designate and train employees to assist in a safe and orderly evacuation of other employees.  a) 1234 South Governors Avenue, Dover, DE 19904 (Throughout): On or about June 23, 2022, the employer failed to train employees in the safe and orderly evacuation procedures to be used at the facility in the event of an emergency.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.157 E01

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $4,972 · Current $3,232 Reduced
29 CFR 1910.157(e)(1):The employer shall be responsible for the inspection, maintenance, and testing of all portable fire extinguishers in the workplace:  a) 1234 South Governors Avenue, Dover, DE 19904 (Throughout): On or about June 23, 2022, the employer failed to conduct yearly, and monthly inspections of the portable fire extinguishers located at the worksite.
Recent events (3)
  • — C (S) $4972
  • — F (S) $3231.8
  • — Z (S) $4972

1910.176 C

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $4,972 · Current $3,232 Reduced
29 CFR 1910.176(c): Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion, or pest harborage:  a) 1234 South Governors Avenue, Dover, DE 19904 (Warehouse): On or about June 23, 2022,  storage areas had accumulation of cardboard boxes of cabinetry building materials and other combustible materials. This exposed employees to pests, trip, fall and fire hazards.
Recent events (3)
  • — C (S) $4972
  • — F (S) $3231.8
  • — Z (S) $4972

1910.178 L01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $4,972 · Current $3,232 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a) 1234 South Governors Avenue, Dover DE 19904 (Warehouse): On or about June 23, 2022, the employer did not ensure the operators of the Toyota Forklift Truck model number 42-4FC20, model number 404FGC25-10913 were competent to operate the power industrial truck safely or as required.
Recent events (3)
  • — C (S) $4972
  • — F (S) $3231.8
  • — Z (S) $4972

1910.213 A12

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $5,801 · Current $3,771 Reduced
29 CFR 1910.213(a)(12):The portion of circular saw(s) beneath or behind the table, where there was a possibility of contact with the saw, was not covered with a guard or exhaust hood).  a) 1234 South Governors Avenue, Dover, DE 19904 (Warehouse): On or about June 23, 2022, the employer permitted employees to use a table saw without a guard or exhaust hood.
Recent events (3)
  • — C (S) $5801
  • — F (S) $3770.65
  • — Z (S) $5801

1910.303 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $4,972 · Current $3,232 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  a) 1234 South Governors Avenue, Dover, DE 19904 (Paint area): On or about June 23, 2022, the employer failed to ensure electrical outlet had a protective cover, exposing employees to the hazards of electrical hazards.
Recent events (3)
  • — C (S) $4972
  • — F (S) $3231.8
  • — Z (S) $4972

1910.303 B06

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(6): Deteriorating agents. Unless identified for use in the operating environment, no conductors or equipment shall be located in damp or wet locations; where exposed to gases, fumes, vapors, liquids, or other agents that have a deteriorating effect on the conductors or equipment; or where exposed to excessive temperatures.  a) 1234 South Governors Avenue, Dover, DE 19904 (Paint Area): On or about June 23, 2022, spray paint operations were conducted in a room not designed for spray painting. Paint over spray was observed on non-intrinsically safe electrical components exposing employees to potential explosion, fire, or electrical shock hazards.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.303 B07

Serious Gravity 10 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7): Mechanical execution of work. Electric equipment shall be installed in a neat and workmanlike manner.  a) 1234 South Governors Avenue, Dover De. 19904 (Paint Area): On or about June 23, 2022, and days prior an electrical junction box was found lying on a shelf with energized wires inside powering the exhaust fan located in the paint area not properly mounted or protected.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.303 B07 III

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(iii): Internal parts of electrical equipment, including busbars, wiring terminals, insulators, and other surfaces, may not be damaged or contaminated by foreign materials such as paint, plaster, cleaners, abrasives, or corrosive residues.  a) 1234 South Governors Avenue, Dover, DE 19904 (Paint Area): On or about June 23, 2022, paint operations were conducted in a room not designed for spray painting. Paint over spray was observed on non-intrinsically safe electrical components exposing employees to potential explosion, fire, or electrical shock hazards.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a) 1234 South Governors Avenue, Dover, DE 19904 (Corian Shop): On or about June 23, 2022, the employer failed to properly identify all circuit breakers inside Cutter-Hammer breaker panel located in the Corian shop to clearly mark their specific purpose.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 2 instances 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a) 1234 South Governors Avenue, Dover, DE 19904 (Paint Area): On or about June 23, 2022, an electrical junction box was found lying on a shelf with energized wires inside powering the exhaust fan located in the paint area not properly mounted or protected.  b) 1234 South Governors Avenue, Dover, DE 19904 (Paint area): On or about June 23, 2022, an electrical outlet did not have a protective cover, exposing employees to the hazards of electrical shock.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.305 A02 X

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $4,972 · Current $3,232 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.  a) 1234 South Governors Avenue, Dover, DE 19904 (Warehouse): On or about June 23, 2022,  an extension cord used to service a 120 V forklift ran beneath an exit doorway and gravel.
Recent events (3)
  • — C (S) $4972
  • — F (S) $3231.8
  • — Z (S) $4972

1910.305 G01 IV B

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:  a) 1234 South Governors Avenue, Dover, DE 19904 (Wood working Shop): On or about June 23, 2022, extension cords were  run through the exterior wall and used as permanent wiring. The extension cord were plugged into a 120 V outlet.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 19, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a) 1234 South Governors Avenue, Dover, DE 19904 (Wood working Shop): On or about June 23, 2022, multiple extension cords did not have proper strain relief. The extension cord was plugged into a 120 V outlet.   b) a) 1234 South Governors Avenue, Dover, DE 19904 (Corian Shop): On or about June 23, 2022, multiple extension cords did not have proper strain relief. The extension cord was plugged into a 120 V outlet.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1904.40 A

Other-than-serious 1 instance 6 exposed
Issued
Dec 19, 2022
Penalty
Initial $829 · Current $539 Reduced
29 CFR 1904.40(a):The employer did not provide an authorized government representative the records within the four business hours.  a) 1234 South Governors Avenue, Dover, DE 19904: On or about June 23, 2022,  the employer failed to provide OSHA 300 logs to a duly authorized government representative within four hours.
Recent events (3)
  • — C (O) $829
  • — F (O) $538.85
  • — Z (O) $829

View Mastercrafters, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346037526.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.