Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SAMSUNG AIR CONDITIONING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SAMSUNG AIR CONDITIONING in AMERICAN SAMOA COMMUNITY COLLEGE VOCATIONAL SCHOOL NEW FACILITY, PAGO PAGO, AS 96799 (NAICS 333415). OSHA activity number 346041882.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Samsung AIR Conditioning — free Get an email when a new federal OSHA severe-injury report for Samsung AIR Conditioning is published. One employer, no account, unsubscribe in one click.
Site address
AMERICAN SAMOA COMMUNITY COLLEGE VOCATIONAL SCHOOL NEW FACILITY
City
PAGO PAGO
State
AS
ZIP
96799
Mailing
P.O. BOX 3170, PAGO PAGO, AS 96799
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
25
Ownership type
A

3 citations on file for this inspection.

1926.303 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2022
Penalty
Initial $3,315 · Current $2,321 Reduced
29 CFR  1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of ANSI B7.1-1970, Safety Code for the Use, Care, and Protection of abrasive wheels, and paragraph (d) of this section.  Third floor: The grinder used to smooth welded pipe for the ceiling frame was missing a guard exposing employees to struck-by hazards
Recent events (2)
  • — I (S) $2320.5
  • — Z (S) $3315

1926.501 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 27, 2022
Abate by
Oct 7, 2022
Penalty
Initial $4,144 · Current $2,901 Reduced
29 CFR  1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  Second floor: Employees cutting metal tubing for the roof frame without fall protection, were exposed to fall up to 15 feet.
Recent events (2)
  • — I (S) $2900.8
  • — Z (S) $4144

1926.1052 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 27, 2022
Abate by
Oct 7, 2022
Penalty
Initial $3,315 · Current $2,321 Reduced
29 CFR 1926.1052(c)(1)(ii): 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with one stairrail system along each unprotected side or edge:  Stairway in front of building: The access to the second level was a stairway with no rails on either open side, exposing employees to fall hazards.
Recent events (2)
  • — I (S) $2320.5
  • — Z (S) $3315

View Samsung AIR Conditioning's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346041882.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.