MCKINNEY, TX —
OSHA Inspection: BANDERA UTILITY CONTRACTORS
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of BANDERA UTILITY CONTRACTORS in 4643 FM 543, MCKINNEY, TX 75071 (NAICS 237110). OSHA activity number 346042393.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BANDERA UTILITY CONTRACTORS
- Site address
- 4643 FM 543
- City
- MCKINNEY
- State
- TX
- ZIP
- 75071
- Mailing
- 416 INTERCHANGE STREET, MCKINNEY, TX 75071
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 130
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.651 K01
- Issued
- Dec 20, 2022
- Abate by
- May 10, 2024
- Penalty
- Initial $13,052 · Current $13,052
General-duty citation text
29 CFR 1926.651(k)(1):Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection was not conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated. On or about June 24, 2022. Employer failed to inspect the trench daily prior to the start of each shift before allowing employees to work in the excavation.
Recent events (3)
- — F (S) $13052
- — C (S) $13052
- — Z (S) $13052
1926.1053 B01
- Issued
- Dec 20, 2022
- Abate by
- May 10, 2024
- Penalty
- Initial $13,052 · Current $13,052
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. On or about June 24, 2022, a portable ladder, within the trench, did not extend 3-feet above the ground level to assist employees in mounting and dismounting the ladder.
Recent events (3)
- — F (S) $13052
- — C (S) $13052
- — Z (S) $13052
1926.1053 B15
- Issued
- Dec 20, 2022
- Abate by
- May 10, 2024
- Penalty
- Initial $9,324 · Current $13,052
General-duty citation text
29 CFR 1926.1053(b)(15):Ladders was not inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use. On or about June 24, 2022. Employer did not inspect extension ladder that was damaged/cut and used by employees for access and egress from the trench.
Recent events (3)
- — F (S) $13052
- — C (S) $9324
- — Z (S) $9324
1926.652 A01
- Issued
- Dec 20, 2022
- Abate by
- May 10, 2024
- Penalty
- Initial $130,524 · Current $60,844 Reduced
General-duty citation text
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when: On or about June 24, 2022. and times prior employees were exposed to cave-in hazard by not having adequate protective system when working inside a 10 foot deep trench.
Recent events (3)
- — F (S) $60844
- — C (W) $130524
- — Z (W) $130524
More inspections at Bandera Utility Contractors
View Bandera Utility Contractors's full OSHA safety record →
More inspections in this industry (NAICS 237110)