OSHA Inspection: MAUSER PACKAGING SOLUTIONS

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of MAUSER PACKAGING SOLUTIONS in 1385 BLATT BLVD, GAHANNA, OH 43230 (NAICS 332439). OSHA activity number 346077928.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mauser Packaging Solutions — free Get an email when a new federal OSHA severe-injury report for Mauser Packaging Solutions is published. One employer, no account, unsubscribe in one click.
Site address
1385 BLATT BLVD
City
GAHANNA
State
OH
ZIP
43230
Mailing
1385 BLATT BLVD, GAHANNA, OH 43230
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332439
Employees
119
Ownership type
A

5 citations on file for this inspection.

1910.107 B01

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Sep 26, 2022
Abate by
Oct 31, 2022
Penalty
Initial $13,674 · Current $0 Reduced
29 CFR  1910.107(b)(1):Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.  a. On or about August 13, 2022, in the Cover Department, the structure of the lid/cover lining spray booth used for spraying flammable paints was partially constructed of combustible materials such as cardboard.  b. On or about August 13, 2022, in the Cover Department, the structure of the exterior lid/cover spray booth used for spraying flammable paints was partially constructed of combustible materials such as cardboard.
Recent events (3)
  • — F (S) $0
  • — C (S) $13674
  • — Z (S) $13674

1910.107 C06

Other-than-serious Gravity 5 2 instances 2 exposed
Issued
Sep 26, 2022
Abate by
Mar 15, 2024
Penalty
Initial $13,674 · Current $0 Reduced
29 CFR  1910.107(c)(6): Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.   a. On or about August 13, 2022, in the Cover Department, the electrical equipment used in the lid/cover lining spray booth was not explosion proof.  b. On or about August 13, 2022, in the Cover Department, the electrical equipment used in the exterior lid/cover spray booth was not explosion proof.
Recent events (3)
  • — F (O) $0
  • — C (S) $13674
  • — Z (S) $13674

1910.107 G02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 26, 2022
Abate by
Dec 18, 2023
Penalty
Initial $13,674 · Current $5,000 Reduced
29 CFR  1910.107(g)(2): Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.  a. On or about August 13, 2022, in the Cover Department, the accumulation of deposits in the exterior lid/cover spray booth were not cleaned.
Recent events (3)
  • — F (S) $5000
  • — C (S) $13674
  • — Z (S) $13674

1910.303 B02

Other-than-serious Gravity 1 1 instance 20 exposed
Issued
Sep 26, 2022
Abate by
Dec 18, 2023
Penalty
Initial $6,837 · Current $5,000 Reduced
29 CFR  1910.303(b)(2):Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  a. On or about July 26, 2022, near the paint booth in the Cover Department, a power strip that was designed for residential use was being used in an industrial setting, which was not in accordance with the listing and labeling of the equipment.
Recent events (3)
  • — F (O) $5000
  • — C (S) $6837
  • — Z (S) $6837

1910.305 G01 IV C

Other-than-serious 1 instance 20 exposed
Issued
Sep 26, 2022
Abate by
Dec 18, 2023
Penalty
Initial $0 · Current $0
1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: 29 CFR  1910.305(g)(1)(iv)(C): Where run through doorways, windows, or similar openings;   a. On or about July 26, 2022, near the paint booth in the Cover Department, a flexible extension cord used to power a pedestal fan was run through an opening of the paint booth wall.