BOULDER CITY, NV —
OSHA Inspection: DEPARTMENT OF THE INTERIOR, BUREAU OF RECLAMATION, HOOVER DAM
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DEPARTMENT OF THE INTERIOR, BUREAU OF RECLAMATION, HOOVER DAM in HOOVER DAM, BOULDER CITY, NV 89006 (NAICS 221111). OSHA activity number 346088024.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- HOOVER DAM
- City
- BOULDER CITY
- State
- NV
- ZIP
- 89006
- Mailing
- PO BOX 60400, BOULDER CITY, NV 89006
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221111
- Employees
- 214
- Ownership type
- D
Citations
3 citations on file for this inspection.
1910.134 F02
- Issued
- Sep 1, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2):Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: Members of the fire brigade who wear tight-fitting elastomeric respirators such as SCBAs, had not been fit tested annually. On July 19, 2022, fire brigade members had responded with SCBAs to fight a transformer fire and had not been fit tested since 2019.
Recent events (1)
- — Z (S) $0
1960.8 C
- Issued
- Sep 1, 2022
- Abate by
- Oct 20, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1960.8(c): The Agency did not develop, implement, and evaluate an occupational safety and health program in accordance with the requirements of section 19 of the Act, Executive Order 12196, and the basic program elements prescribed in this part, or approved alternate program elements: July 19, 2022: Although written Emergency Action Plan procedures were developed, the procedures were inadequate or incorrectly implemented which contributed to confusion and delay in the emergency response to a transformer bushing fire. The inadequate or incorrectly implemented procedures included; 1. The page communication system did not deliver a clear and concise notification and direction, 2. A secondary assembly point was not established (the fire took place at the only established assembly point), 3. Personnel accountability was not obtained during and after the incident, and 4. Personnel responsible for providing emergency response support activities to prevent hazards such as heat-related illnesses for employees engaged in firefighting were not established.
Recent events (1)
- — Z (S) $0
1910.157 E03
- Issued
- Sep 1, 2022
- Abate by
- Sep 28, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Fire Brigade Area, Hose Cart: Three fire extinguishers had not received an annual maintenance check since December 2017.
Recent events (1)
- — Z (O) $0
More inspections at Department of the Interior, Bureau of Reclamation, Hoover DAM
View Department of the Interior, Bureau of Reclamation, Hoover DAM's full OSHA safety record →
More inspections in this industry (NAICS 221111)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346088024.