Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COAL AGE, INCORPORATED DBA PHILLIPS GLOBAL

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of COAL AGE, INCORPORATED DBA PHILLIPS GLOBAL in 2736 KEN GRAY BLVD, WEST FRANKFORT, IL 62896 (NAICS 333131). OSHA activity number 346091499.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coal AGE, Incorporated DBA Phillips Global — free Get an email when a new federal OSHA severe-injury report for Coal AGE, Incorporated DBA Phillips Global is published. One employer, no account, unsubscribe in one click.
Site address
2736 KEN GRAY BLVD
City
WEST FRANKFORT
State
IL
ZIP
62896
Mailing
2736 KEN GRAY BLVD, WEST FRANKFORT, IL 62896
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333131
Employees
24
Ownership type
A

16 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $11,188 · Current $7,272 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  Phillips Global main building, spraying area, northwest wall: On or about 20 July 2022 and 29 September 2022, an exit route door was  sealed shut with a piece of wood, hindering exit access for employees in the event of an emergency.
Recent events (2)
  • — I (S) $7272
  • — Z (S) $11188

1910.37 B06

Serious Gravity 5 1 instance 24 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  Main Phillips Global building, spraying area, northwest wall: On or about 20 July 2022 and 29 September 2022, the exit route door sign was indistinguishable, not illuminated and coated with multiple layers of residual paint making it difficult in the event of an emergency to determine the location of the only exit route door in the spraying area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E09 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $11,188 · Current $7,272 Reduced
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:  Main Phillips Global building, northwest, spraying area: On or about 20 July 2022, employees did not store combustible waste material and residues in a covered metal receptacle and materials were not disposed of daily.  Combustible waste materials were stored uncovered in a metal drum after draining residuals into an enclosed drum.  Covered and uncovered, full, half-full and empty paint cans were observed next to the flammable storage locker and were allowed to accumulate.
Recent events (2)
  • — I (S) $7272
  • — Z (S) $11188

1910.107 G03

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(3): Approved metal waste cans were not provided where rags or waste were impregnated with finishing material were deposited and the contents of those waste cans were not properly disposed of at least once daily or at the end of each shift:  Main Phillips Global building, southwest, spraying area: On or about 20 July 2022 and 29 September 2022, employees did not store combustible waste material and residues in a covered metal receptacle and did not disposed of daily.  Paint waste materials, nitrile gloves used for painting and paint saturated painting tape were located inside an uncovered metal drum that was also used for general trash.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $11,188 · Current $7,272 Reduced
29 CFR 1910.107(c)(2): Open flame or spark producing equipment was not kept from a spraying area nor within 20 feet and wasn't separated from by a partition:  Main Phillips Global building, northwest, spraying area: On or about 20 July 2022, a Graco Nova 390 PC Electric Airless paint sprayer was found within the spraying area and within 20 feet without a partition.  A label on the sprayer indicates that the sprayer generates sparks and is equipped with warning labels.
Recent events (2)
  • — I (S) $7272
  • — Z (S) $11188

1910.107 C07

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.107(c)(7): Electric lamps outside of but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not totally enclosed to prevent the falling of hot particles:  Main Phillips Global building, northwest, spraying area: On or about 20 July 2022, there were approximately 8 fluorescent "shop light" type light fixtures that were not enclosed to prevent the falling of hot particles located in the spraying room/spraying area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 E02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $11,188 · Current $7,272 Reduced
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift:  Main Phillips Global building, northwest, spraying area: On or about 20 July 2022, approximately 10 marked containers of flammable and combustible liquids were observed sitting next to and across from the hazardous materials locker.  The hazardous materials locker was located on the northeast wall of the spraying area and a variety of uncovered and covered flammable liquid cans were sitting just south of the locker.  Additionally, there were more flammable liquid containers located on the west wall of the spraying area.
Recent events (2)
  • — I (S) $7272
  • — Z (S) $11188

1910.107 E05

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $11,188 · Current $7,272 Reduced
29 CFR 1910.107(e)(5): Containers supplying spray nozzles shall be of closed type or provided with metal covers kept closed:  Main Phillips Global building, northwest, spraying area: On or about 20 July 2022 and 29 September 2022, a container supplying a Graco Nova 390 PC Electric Airless paint sprayer nozzle was not a closed type and was not kept closed with a metal cover.
Recent events (2)
  • — I (S) $7272
  • — Z (S) $11188

1910.107 G02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $11,188 · Current $7,272 Reduced
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:  Main Phillips Global building, northwest, spraying area: On or about 20 July 2022, the spraying area was not kept free from accumulation of deposits of combustible residues as there was residue in the container holding the spray nozzles, visible paint residue on the floor of the facility and on materials used to protect the floor from spray.
Recent events (2)
  • — I (S) $7272
  • — Z (S) $11188

1910.134 C01

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $5,594 · Current $3,636 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:   Main Phillips Global building, spray area and blast cleaning facility: On or about 20 July 2022, the employer did not have a written respiratory protection program specific to the facility, but required respirator usage during painting and blast cleaning operations.
Recent events (2)
  • — I (S) $3636
  • — Z (S) $5594

1910.134 D01 III

Serious Gravity 1 1 instance 24 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  Main Phillips Global building: On or about 20 July 2022, the employer didn't identify and evaluate respiratory hazards in the workplace but required employees to wear tight-fitting half face respirators during painting operations and a Bullard 88VX Series Respirator Helmet Assembly w/supplied air for blast cleaning.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 12, 2023
Abate by
Feb 27, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  Main Phillips Global building: On or about 20 July 2022 the employer did not provide a medical evaluation to determine an employee's ability to use a respirator. The employer required employees to wear half-face respirators for painting operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  Phillips Global, main building, northwest, spraying area:  On or about 20 July 2022, the employer did not fit test to determine an employee's ability to use a respirator. The employer required employees to wear tight-fitting facepiece respirators for painting operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H01

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(1): Respirators were not cleaned and disinfected using the procedures in Appendix B-2 of 29 CFR 1910.134 or equivalent procedures recommended by the respirator manufacturer:  Phillips Global, main building, northwest, spraying area: On or about 20 July 2022, the employer required employees to wear half-face respirators for painting operations and a respirator helmet assembly with supplied air for blast cleaning operations but didn't have a cleaning or disinfecting process in accordance with Appendix B-2 of 29 CFR 1910.134.  An employee presented a personally procured Gerson 9250 Silicone face piece size medium that was covered in dust, paint, debris and the Gerson G01 organic vapor cartridge filters had a layer of visible paint and dust.  Additionally, an employee presented an employer supplied Bullard 88VX Series Respirator Helmet Assembly w/supplied air for blasting operations also covered in dust and debris.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 12, 2023
Abate by
Feb 8, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve:  Phillips Global, main building, northwest, spraying area and blasting area: On or about 20 July 2022, the employer required employees to wear half-face respirators for painting operations and a respirator helmet assembly with supplied air for blast cleaning operations.  An employee took a personally procured Gerson 9250 Silicone face piece size medium out of his toolbox covered in dust, paint, debris and the Gerson G01 organic vapor cartridge filters had a layer of visible paint and dust.  Additionally, on 20 July 2022 and 29 September, a Bullard 88VX Series Respirator Helmet Assembly w/supplied air for blasting operations was being stored in the blasting area and another being stored in a dusty room also covered in dust.  Neither piece of equipment had a proper storage mechanism or designated area to ensure protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 12, 2023
Penalty
Initial $7,458 · Current $4,848 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:   Main Phillips Global building, northwest, spray area: On or about 20 July 2022, employees in the spray area were exposed to chemical hazards while working in an environment with flammable paint, flammable solvents and related chemicals and didn't receive hazard communication training related to these hazards.