Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNDERGROUND UTILITIES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UNDERGROUND UTILITIES INC. in 143 ARMOUR RD., AVON LAKE, OH 44012 (NAICS 237110). OSHA activity number 346092745.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Underground Utilities INC. — free Get an email when a new federal OSHA severe-injury report for Underground Utilities INC. is published. One employer, no account, unsubscribe in one click.
Site address
143 ARMOUR RD.
City
AVON LAKE
State
OH
ZIP
44012
Mailing
416 W. MONROE ST., MONROEVILLE, OH 44847
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
8
Ownership type
A

1 citation on file for this inspection.

1926.652 G02

Repeat Gravity 5 1 instance 2 exposed
Issued
Jan 13, 2023
Abate by
Jan 19, 2023
Penalty
Initial $18,231 · Current $9,116 Reduced
29 CFR  1926.652(g)(2): Additional requirement for shield systems used in trench excavations. Excavations of earth material to a level not greater than 2 feet (.61 m) below the bottom of a shield shall be permitted, but only if the shield is designed to resist the forces calculated for the full depth of the trench, and there are no indications while the trench is open of a possible loss of soil from behind or below the bottom of the shield:  On or about July 21, 2022, at jobsite located at 143 Armour Road, Avon Lake, OH 44012, Underground Utilities Inc. permitted its employees to enter the trench and perform work without ensuring that the bottom of the shielding system was no more than two (2) feet above the bottom of the trench. The employees were working at the bottom of a 7 feet deep trench inside of a 6 foot high X 2 foot 6 tenths wide stackable trench shield box with 2 feet and 4 tenths of unshielded soil from the bottom of the trench shield box to the trench base.  Underground Utilities Inc. was previously cited for a violation of this Occupational Safety and Health Standard 1926.652(g)(2), which was contained in OSHA inspection number 1392508, citation number one, item number one and was affirmed as a final order on May 14, 2019, with respect to a workplace located at 1895 Cooper Forest, Amherst, OH 44001.
Recent events (3)
  • — F (R) $9116
  • — C (R) $18231
  • — Z (R) $18231

View Underground Utilities INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346092745.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.