AVON LAKE, OH —
OSHA Inspection: UNDERGROUND UTILITIES INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UNDERGROUND UTILITIES INC. in 143 ARMOUR RD., AVON LAKE, OH 44012 (NAICS 237110). OSHA activity number 346092745.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNDERGROUND UTILITIES INC.
- Site address
- 143 ARMOUR RD.
- City
- AVON LAKE
- State
- OH
- ZIP
- 44012
- Mailing
- 416 W. MONROE ST., MONROEVILLE, OH 44847
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 8
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.652 G02
- Issued
- Jan 13, 2023
- Abate by
- Jan 19, 2023
- Penalty
- Initial $18,231 · Current $9,116 Reduced
General-duty citation text
29 CFR 1926.652(g)(2): Additional requirement for shield systems used in trench excavations. Excavations of earth material to a level not greater than 2 feet (.61 m) below the bottom of a shield shall be permitted, but only if the shield is designed to resist the forces calculated for the full depth of the trench, and there are no indications while the trench is open of a possible loss of soil from behind or below the bottom of the shield: On or about July 21, 2022, at jobsite located at 143 Armour Road, Avon Lake, OH 44012, Underground Utilities Inc. permitted its employees to enter the trench and perform work without ensuring that the bottom of the shielding system was no more than two (2) feet above the bottom of the trench. The employees were working at the bottom of a 7 feet deep trench inside of a 6 foot high X 2 foot 6 tenths wide stackable trench shield box with 2 feet and 4 tenths of unshielded soil from the bottom of the trench shield box to the trench base. Underground Utilities Inc. was previously cited for a violation of this Occupational Safety and Health Standard 1926.652(g)(2), which was contained in OSHA inspection number 1392508, citation number one, item number one and was affirmed as a final order on May 14, 2019, with respect to a workplace located at 1895 Cooper Forest, Amherst, OH 44001.
Recent events (3)
- — F (R) $9116
- — C (R) $18231
- — Z (R) $18231
More inspections at Underground Utilities INC.