1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: SHIOCTON CUT STOCK LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SHIOCTON CUT STOCK LLC in W7824 SMITH STREET, SHIOCTON, WI 54170 (NAICS 321912). OSHA activity number 346096357.

Watch Shiocton CUT Stock LLC — free Get an email when a new federal OSHA severe-injury report for Shiocton CUT Stock LLC is published. One employer, no account, unsubscribe in one click.
Site address
W7824 SMITH STREET
City
SHIOCTON
State
WI
ZIP
54170
Mailing
W7824 SMITH STREET, SHIOCTON, WI 54170
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321912
Employees
35
Ownership type
A

3 citations on file for this inspection.

1910.147 D

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $10151.00 · Current $0.00 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedure) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6):  On or about July 18, 2022, an employee was exposed to hazardous energy sources when performing maintenance and servicing on the Timberland 5 Head Resaw Notcher, because the employee did not effectively isolate all energy sources.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10151

1910.147 C04 II

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $6091.00
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section.  a.	On or about July 21, 2022, the employer failed to provide energy control English procedures which clearly and specifically outlined the isolation steps to be taken to control the pneumatic hazardous energy for the Timberland 5 Head Resaw Notcher, exposing employees to potential amputation injuries.  b.	On or about July 21, 202, the employer failed to provide energy control Spanish procedures which clearly and specifically outlined the isolation steps to be taken to control the pneumatic hazardous energy for the Timberland 5 Head Resaw Notcher, exposing employees to potential amputation injuries.
Recent events (2)
  • — I (S) $6090.6
  • — Z (S) $0

1910.147 C06 I B

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i)(B): The employer did not conduct a periodic inspection of the energy control procedure and correct any deviations or inadequacies.  a.	On or about June 6, 2022, the employer failed to identify and correct deviations or inadequacies found in the control of hazardous energy procedure for the          Timberland 5 Head Resaw Notcher.  b.	On or about June 13, 2022, the employer failed to identify and correct deviations or inadequacies found in the control of hazardous energy procedure for           the Timberland 5 Head Resaw Notcher.  c.	On or about September 21, 2022, the employer failed to identify and correct deviations or inadequacies found in the control of hazardous energy procedure          for the Timberland 5 Head Resaw Notcher.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View SHIOCTON CUT STOCK LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346096357.