Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WEST RIVER ELECTRIC ASSOCIATION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WEST RIVER ELECTRIC ASSOCIATION, INC. in 15571 SOUTH ANTELOPE CREEK ROAD, RAPID CITY, SD 57703 (NAICS 221122). OSHA activity number 346098676.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch West River Electric Association, INC. — free Get an email when a new federal OSHA severe-injury report for West River Electric Association, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15571 SOUTH ANTELOPE CREEK ROAD
City
RAPID CITY
State
SD
ZIP
57703
Mailing
3250 SOUTH DAKOTA 44, RAPID CITY, SD 57703
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221122
Employees
56
Ownership type
A

1 citation on file for this inspection.

1926.960 E03

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Dec 15, 2022
Abate by
Jan 12, 2023
Penalty
Initial $14,502 · Current $12,000 Reduced
29 CFR 1926.960(d)(1) Working from below. The employer shall ensure that each employee, to the extent that other safety-related conditions at the worksite permit, works in a position from which a slip or shock will not bring the employee's body into contact with exposed, uninsulated parts energized at a potential different from the employee's:  29 CFR 1926.960(e)(3) Loose conductors. When lines or equipment are connected to or disconnected from energized circuits, the employee shall keep loose conductors away from exposed energized parts:  (a)West River Electric Association, Inc. at 15571 South Antelope Creek Road, Rapid City, SD 57703: On or about and at times prior to June 30, 2022, the employer did not ensure groundmen were protected from electrical shock by work-positioning in the event secondary cables became energized during meter loop installation. On June 30, 2022, a groundman suffered serious injuries including electrical shock and burns after secondary wires held by a lineman contacted the primary jumper. High voltage current traveled down the secondary cable into the meter loop where the groundman was in the process of securing the meter loop to the pole.  The current arced from the meter lug to the injured employee's hand traveling through their body and exiting through the gluteal area.
Recent events (2)
  • — I (O) $12000
  • — Z (S) $14502

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346098676.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.