Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PUNCH BOWL SOCIAL AUSTIN

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of PUNCH BOWL SOCIAL AUSTIN in 11310 DOMAIN DRIVE, AUSTIN, TX 78758 (NAICS 722511). OSHA activity number 346112238.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Punch Bowl Social Austin — free Get an email when a new federal OSHA severe-injury report for Punch Bowl Social Austin is published. One employer, no account, unsubscribe in one click.
Site address
11310 DOMAIN DRIVE
City
AUSTIN
State
TX
ZIP
78758
Mailing
11310 DOMAIN DRIVE, AUSTIN, TX 78758
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722511
Employees
25
Ownership type
A

4 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 8 instances 9 exposed
Issued
Jan 26, 2023
Abate by
Mar 10, 2023
Penalty
Initial $15,625 · Current $9,487 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  On or about July 28, 2022, and at times prior thereto, the employer did not establish an adequate program consisting of energy control procedures, employee training and periodic inspections where employees were performing maintenance on the  Kebo Pin Setter Bowling Machine, exposing employees to caught-in hazards.
Recent events (2)
  • — I (S) $9487.25
  • — Z (S) $15625

1910.147 C05 I

Deleted Serious Gravity 5 8 instances 9 exposed
Issued
Jan 26, 2023
Abate by
Feb 7, 2023
Penalty
Initial $11,162 · Current $0 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources. The employer did not provide locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware as required.  On or about July 28, 2022, and at times prior thereto, the employer did not provide energy isolating devices to employees who were performing maintenance on the Kebo Pin Setter Bowling Machine, exposing employees to caught-in hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11162

1910.219 F03

Deleted Serious Gravity 5 8 instances 9 exposed
Issued
Jan 26, 2023
Abate by
Feb 7, 2023
Penalty
Initial $11,162 · Current $0 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains that were seven (7) or less feet from the floor or platform were not enclosed:  a) On or about July 28, 2022, and at times prior thereto, located at the rear of the Kebo Pin Setter Bowling Machines, employees retrieving bowling balls and releasing stuck pins were exposed to unguarded chains and sprockets driving the ball return mechanisms, exposing the employees to caught-in hazards.  b) On or about July 28, 2022, and at times prior thereto, employees accessing the front and back of the Kebo Pin Setter Bowling Machines were exposed to unguarded chains and sprockets driving the pin setters, exposing the employees to caught-in hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11162

1910.212 A02

Other-than-serious Gravity 5 8 instances 9 exposed
Issued
Jan 26, 2023
Abate by
Mar 10, 2023
Penalty
Initial $0 · Current $9,487
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible.  On or about July 28, 2022, and at times prior thereto, machine guarding for the ball return mechanism on the Kebo Pin Setter Bowling Machines were not affixed to the machine, exposing employees to potential hazards.
Recent events (2)
  • — I (O) $9487.25
  • — Z (S) $0

View Punch Bowl Social Austin's full OSHA safety record →