OSHA Inspection: O'DANNY BOY BUILDERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of O'DANNY BOY BUILDERS, INC. in 5117 NORTH WATERFORD DRIVE, APPLETON, WI 54913 (NAICS 238160). OSHA activity number 346114838.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch O'Danny BOY Builders, INC. — free Get an email when a new federal OSHA severe-injury report for O'Danny BOY Builders, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5117 NORTH WATERFORD DRIVE
City
APPLETON
State
WI
ZIP
54913
Mailing
7512 S COUNTY LINE RD SUITE 4, BURR RIDGE, IL 60527
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 6 exposed
Issued
Oct 13, 2022
Penalty
Initial $5,801 · Current $4,061 Reduced
29 CFR  1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  On or about May 19, 2022, at the worksite located at 5117 North Waterford Drive, Appleton, WI 54913, the employer did not ensure that a competent person was performing frequent and regular inspections that could have recognized the fall from elevation hazards. Subcontractor employees were exposed to fall hazards while performing residential construction work on a roof without fall protection. The eave height of the roof was greater than 9 feet and the roof pitch was approximately 5/12.
Recent events (2)
  • — I (S) $4060.7
  • — Z (S) $5801

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 13, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.   On or about May 19, 2022, at the worksite located at 5117 North Waterford Drive, Appleton, WI 54913, the employer did not ensure that each subcontractor employee working on a roof was protected from falls, exposing subcontractor employees to fall hazards. The eave height of the roof was greater than 9 feet and the roof pitch was approximately 5/12.   Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 13, 2022
Abate by
Nov 10, 2022
Penalty
Initial $3,315 · Current $2,321 Reduced
29 CFR  1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.  On or about May 19, 2022, at the worksite located at 5117 North Waterford Drive, Appleton, WI 54913, the employer did not ensure that an employee exposed to struck by hazards while working on the ground below employees working on a residential roof wore a hard hat.