PHILADELPHIA, PA —
OSHA Inspection: TERENCE FROMAN, INC. DBA FROMAN EXCAVATING
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TERENCE FROMAN, INC. DBA FROMAN EXCAVATING in 3401 CHESTNUT ST, PHILADELPHIA, PA 19104 (NAICS 238910). OSHA activity number 346118250.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TERENCE FROMAN, INC. DBA FROMAN EXCAVATING
- Site address
- 3401 CHESTNUT ST
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19104
- Mailing
- 5660 EASTON RD, PIPERSVILLE, PA 18947
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 9
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 26, 2023
- Abate by
- Feb 14, 2023
- Penalty
- Initial $6,250 · Current $5,000 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1) The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees Respondent Terence Froman, Inc. d/b/a Froman Excavating, did not furnish employment and a place of employment which were free 2 from recognized hazards that caused or were likely to cause death or serious physical harm. a) Jobsite located at or near 4301 Chestnut St., Philadelphia, PA ? On or about September 14, 2022, the employer did not ensure scaffolding platforms were at least 18 inches wide. b) Jobsite located at or near 4301 Chestnut St., Philadelphia, PA ? On or about September 14, 2022, the employer did not ensure wooden planks utilized by employees to access scaffold platforms were equipped with guardrails.
Recent events (3)
- — R (S) $5000
- — C (S) $6250
- — Z (S) $6250
1926.451 E05 I
- Issued
- Jan 26, 2023
- Abate by
- Feb 14, 2023
- Penalty
- Initial $6,250 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(e)(5)(i): Ramps and walkways 6 feet or more above lower levels did not have guardrail systems that comply with subpart M of this part -- Fall Protection: a) Jobsite located at or near 3401 Chestnut St, Philadelphia, PA - On or about September 14, 2022, the employer did not ensure wooden planks approximately 9 feet above the ground utilized by employees to access scaffold platforms, attached to the face of cast in-place concrete forms were equipped with guardrails; thereby exposing employees to fall hazards.
Recent events (3)
- — R (S) $0
- — C (S) $6250
- — Z (S) $6250
1926.651 C02
- Issued
- Jan 26, 2023
- Penalty
- Initial $2,678 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Jobsite located at or near 3401 Chestnut St, Philadelphia, PA - On or about July 28, 2022, the employer did not ensure a stairway, ladder, ramp or other safe means of egress was located in a trench approximately 8 feet in depth so as to require no more than 25 feet of lateral travel for employees working in the excavation.
Recent events (3)
- — R (S) $0
- — C (S) $2678
- — Z (S) $2678
1926.651 H01
- Issued
- Jan 26, 2023
- Abate by
- Feb 14, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(h)(1): The employer did not provide adequate precautions to protect employees who were working in excavations and were exposed to the hazard of an accumulation of water: a) Jobsite located at or near 3401 Chestnut St, Philadelphia, PA - On or about July 28, 2022, the employer did not provide precautions to protect employees who were working in excavations and were exposed to the hazard of an accumulation of water.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1926.651 K01
- Issued
- Jan 26, 2023
- Abate by
- Feb 14, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection was not conducted by the competent person prior to the start of work and as needed throughout the shift. a) Jobsite located at or near 3401 Chestnut St, Philadelphia, PA - On or about July 28, 2022, the employer did not ensure daily inspections of excavations were made by a competent person prior to the start of work, as needed throughout the shift and for evidence of a situation that could result in hazardous conditions, such as lack of egress and accumulation of water, exposing employees to struck-by hazards.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Jan 26, 2023
- Penalty
- Initial $3,036 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet above the upper landing surface to which the ladder was used to gain access: a) Jobsite located at or near 3401 Chestnut St, Philadelphia, PA - On or about September 14, 2022, the employer did not ensure the side rails of portable ladders used for access to an upper landing surface extended at least 3 feet above the upper landing surface being accessed. Employees utilized a portable ladder to access a scaffold platform attached to the face of cast in-place concrete forms without having side rails extended at least 3 feet above the landing surface, thereby exposing employees to fall hazards.
Recent events (3)
- — R (S) $0
- — C (S) $3036
- — Z (S) $3036
More inspections at Terence Froman, INC. DBA Froman Excavating
View Terence Froman, INC. DBA Froman Excavating's full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346118250.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.