CHICAGO, IL —
OSHA Inspection: MSF CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MSF CONSTRUCTION INC. in 2768 N ASHLAND AVE, CHICAGO, IL 60614 (NAICS 238140). OSHA activity number 346126394.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MSF CONSTRUCTION INC.
- Site address
- 2768 N ASHLAND AVE
- City
- CHICAGO
- State
- IL
- ZIP
- 60614
- Mailing
- 150 E NORTHWEST HWY APT B, DES PLAINES, IL 60016
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B10
- Issued
- Dec 12, 2022
- Abate by
- Jan 9, 2023
- Penalty
- Initial $4,351 · Current $2,610 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) On or about August 4, 2022, employees performing roofing work were exposed to fall hazards from the roof of a 3 story building. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2610
- — Z (S) $4351
More inspections in this industry (NAICS 238140)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346126394.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.