METTER, GA —
OSHA Inspection: C & R INDUSTRIAL SERVICES, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of C & R INDUSTRIAL SERVICES, INC. in 11392 TURNER RD, METTER, GA 30439 (NAICS 811310). OSHA activity number 346127681.
Where did this inspection happen?
- Establishment
- C & R INDUSTRIAL SERVICES, INC.
- Site address
- 11392 TURNER RD
- City
- METTER
- State
- GA
- ZIP
- 30439
- Mailing
- 118 DOY LANIER ROAD, STATESBORO, GA 30458
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 14
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.333 A
- Issued
- Abate by
- Penalty
- Initial $14502.00 · Current $14502.00
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized: a) At the rotary phase convertor for a center pivot, located at 11392 Turner Rd., Metter, GA, 30439, on or about August 4, 2022, the employer exposed employees to electrical shock hazards, in that the employer did not require employees to deenergize electrical circuits while performing electrical maintenance.
Recent events (2)
- — I (S) $14502
- — Z (S) $14502
1910.335 A01 I
- Issued
- Abate by
- Penalty
- Initial $5801.00 · Current $2650.00 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: a) At the rotary phase convertor for a center pivot, located at 11392 Turner Rd., Metter, GA, 30439, on or about August 4, 2022, the employer exposed employees to electrical shock hazards, in that the employer did not provide Personal Protective Equipment to employees performing electrical installations and maintenance.
Recent events (2)
- — I (S) $2650
- — Z (S) $5801
1910.335 A02 I
- Issued
- Abate by
- Penalty
- Initial $5801.00 · Current $2650.00 Reduced
General-duty citation text
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts: a) At the rotary phase convertor for a center pivot, located at 11392 Turner Rd., Metter, GA, 30439, on or about August 4, 2022, the employer exposed employees to electrical shock hazards, in that the employer did not ensure employees used insulated tools or handling equipment while performing electrical installations and maintenance.
Recent events (2)
- — I (S) $2650
- — Z (S) $5801
1904.4 A
- Issued
- Abate by
- Penalty
- Initial $829.00 · Current $379.00 Reduced
General-duty citation text
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent. a) At the main office, 118 Doy Lanier Road, Statesboro, GA, 30458, on or about August 4, 2022, the employer did not record the following workplace injuries or illness on the OSHA 300 or equivalent for the calendar year 2022. On April 25, 2022, an employee suffered an intra-articular fracture of the distal radius extending into the radial styloid from falling off of a ladder while performing work on an agricultural pivot. Abatement Certification and Documentation is required
Recent events (2)
- — I (O) $379.1
- — Z (O) $829
1904.39 A01
- Issued
- Penalty
- Initial $4144.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1904.39(a)(1):The employer did not report within 8-hours the death of an employee resulting from a work-related incident. a) At 118 Doy Lanier Road, Statesboro, GA 30458, on or about August 4, 2022, the employer failed to report the death of an employee resulting from a work-related incident within 8 hours.
Recent events (2)
- — I (O) $1500
- — Z (O) $4144
More inspections in this industry (NAICS 811310)
CHRISTIANSBURG, VA—2026-07-09
BGIS GLOBAL INTEGRATED SOLUTION US, LLC
SEATTLE, WA—2026-07-09
WA317992010 - FLAGSHIP MANAGEMENT LLC
STATESBORO, GA—2026-07-08
TAYLOR BUILT PRODUCTS
, AK—2026-07-08
ANGUS ENTERPRISES
LOS ANGELES, CA—2026-07-08
CHILLEST INDUSTRIES LLC
More inspections in GA
GREENSBORO, GA—2026-07-16
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346127681.