Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BELLSOUTH TELECOMMUNICATIONS, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of BELLSOUTH TELECOMMUNICATIONS, LLC in 2 CLUB CIRCLE, ELLENWOOD, GA 30294 (NAICS 517311). OSHA activity number 346127699.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bellsouth Telecommunications, LLC — free Get an email when a new federal OSHA severe-injury report for Bellsouth Telecommunications, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2 CLUB CIRCLE
City
ELLENWOOD
State
GA
ZIP
30294
Mailing
285 RACETRACK ROAD, MCDONOUGH, GA 30252
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
517311
Employees
35
Ownership type
A

2 citations on file for this inspection.

1910.268 J03

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Feb 1, 2023
Abate by
Mar 21, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.268(j)(3): Vehicle-mounted elevating and rotating work platforms were operated with conductive parts of the equipment closer to exposed energized power lines than the clearances set forth in Table R-2 of this section.  a) Site, 2 Club Circle, Ellenwood, GA 30294; on or about August 2, 2022, outside field technicians (OPT) installing aerial fiber optic cables on electrical poles were exposed to electrical shock and burn hazards, in that the employer did not ensure that vehicle-mounted elevating and rotating work platforms were not operated with any conductive part of the equipment closer to exposed energized power lines that the clearances set forth in Table R-2 of this section to prevent accidental contact with the energized lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

1910.268 B07 II

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Feb 1, 2023
Abate by
Mar 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.268(b)(7)(ii): The employer did not ensure that no employee approaches or takes any conductive object closer to any electrically energized overhead power lines and parts than prescribed in Table R-2, unless the energized parts are insulated or guarded from the employee and any other conductive object at a different potential.   a) Site, 2 Club Circle, Ellenwood, GA 30294; on or about August 2, 2022, outside field technicians (OPT) installing aerial fiber optic cables on electrical poles were exposed to electrical shock and burn hazards, in that the employer did not ensure that no employee takes conductive parts of vehicle-mounted elevating and rotating work platforms closer  to electrically energized overhead power lines than prescribed in Table R-2 of this section, unless the energized parts are insulated or guarded to prevent accidental contact with the energized lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Bellsouth Telecommunications, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346127699.