OSHA Inspection: MTM BUILDING & ROOFING CONTRACTORS LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of MTM BUILDING & ROOFING CONTRACTORS LLC in 714 OLIVIA STREET, KEY WEST, FL 33040 (NAICS 238160). OSHA activity number 346135742.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MTM Building & Roofing Contractors LLC — free Get an email when a new federal OSHA severe-injury report for MTM Building & Roofing Contractors LLC is published. One employer, no account, unsubscribe in one click.
Site address
714 OLIVIA STREET
City
KEY WEST
State
FL
ZIP
33040
Mailing
1724 FLAGLER AVENUE, KEY WEST, FL 33040
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 2, 2023
Penalty
Initial $15,625 · Current $10,938 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:   On or about August 3, 2022, at a worksite located at 714 Olivia Street, Key West, Florida, 33040, employees were exposed to an electrocution hazard when working with sharp tools, such as utility knives and metal roofing panels with sharp edges within 6 inches of an energized insulated powerline.
Recent events (2)
  • — I (S) $10937.5
  • — Z (S) $15625

1926.416 A03

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 2, 2023
Abate by
Feb 14, 2023
Penalty
Initial $0 · Current $0
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit:   On or about August 3, 2022, at a worksite located at 714 Olivia Street, Key West, Florida, 33040, employees were exposed to an electrocution hazard when working with sharp tools within 6 inches of an energized insulated powerline and were not informed of protective measures needed to avoid contact with the energized lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.39 A01

Other-than-serious 1 instance 1 exposed
Issued
Feb 2, 2023
Abate by
Feb 8, 2023
Penalty
Initial $3,349 · Current $2,009 Reduced
29 CFR 1904.39(a)(1): The employer did not report within 8-hours the death of an employee resulting from a work-related incident:   On or about August 3, 2022, at a worksite located at 714 Olivia Street, Key West, Florida, 33040, the employer did not report to OSHA within 8-hours a work-related death of an employee.
Recent events (2)
  • — I (O) $2009.4