OSHA Inspection: ARC CONTRACTING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARC CONTRACTING in 1509 NORTH LILAS DRIVE, APPLETON, WI 54914 (NAICS 238160). OSHA activity number 346148141.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ARC Contracting — free Get an email when a new federal OSHA severe-injury report for ARC Contracting is published. One employer, no account, unsubscribe in one click.
Establishment
ARC CONTRACTING
Site address
1509 NORTH LILAS DRIVE
City
APPLETON
State
WI
ZIP
54914
Mailing
2300 HOLLY RD., NEENAH, WI 54956
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
20
Ownership type
A

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 30, 2022
Abate by
Sep 28, 2022
Penalty
Initial $5,801 · Current $5,801
29 CFR  1926.20(b)(2):Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  On or about August 12,  2022, at a work site located at 1509 N. Lilas Drive Appleton, WI:  the employer did not address construction hazards by having frequent and regular inspections of the worksite by a competent person to ensure sub-contractors were following company and OSHA safety regulations to include the use of fall protection. Five subcontractors were exposed to falls of more than eight feet while on the roof without fall protection.
Recent events (1)
  • — Z (S) $5801

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 30, 2022
Abate by
Sep 28, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  On or about August 12, 2022, at a worksite located at 1509 N. Lilas Drive Appleton, WI 54914, 5 subcontractors of ARC Contracting were performing residential roofing activities without any form of conventional fall protection while exposed to falls of approximately eight feet five inches to 18 feet.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 30, 2022
Abate by
Sep 28, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  On or about August 12, 2022, at a worksite located at 1509 N. Lilas Drive Appleton, WI 54914: employees were utilizing a metal extension ladder and were exposed to a fall hazard of approximately eight feet three inches, as the ladder used for accessing and egressing the roof did not extend three feet above the roof edge.
Recent events (1)
  • — Z (S) $0

1926.1053 B05 I

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 30, 2022
Abate by
Sep 28, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(5)(i):Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).  On or about August 12, 2022, at a worksite located at 1509 N. Lilas Drive Appleton, WI 54914: the horizontal distance from the vertical support to the base of the extension ladder which was used by the employees to access a roof was more than one fourth (1/4) the working length of the ladder.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346148141.