Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EMP SHIELD, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EMP SHIELD, INC. in 2010 SOUTH 6TH STREET, BURLINGTON, KS 66839 (NAICS 334418). OSHA activity number 346151848.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch EMP Shield, INC. — free Get an email when a new federal OSHA severe-injury report for EMP Shield, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
EMP SHIELD, INC.
Site address
2010 SOUTH 6TH STREET
City
BURLINGTON
State
KS
ZIP
66839
Mailing
2010 SOUTH 6TH STREET, BURLINGTON, KS 66839
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334418
Employees
56
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 1, 2022
Abate by
Jan 5, 2023
Penalty
Initial $5,801 · Current $3,770 Reduced
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  In the clean room, employees engaged in production activities were exposed to struck-by and electrical hazards. An inclusive written energy control program had not been established by the employer.
Recent events (2)
  • — I (S) $3770
  • — Z (S) $5801

1910.147 C04 I

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 1, 2022
Abate by
Jan 20, 2023
Penalty
Initial $5,801 · Current $3,770 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  In the clean room, employee(s) were exposed to struck-by and electrical hazards in that machine specific procedures had not been developed for the MAI-H4T Automatic Insertion System with electrical and pneumatic energy sources.
Recent events (2)
  • — I (S) $3770
  • — Z (S) $5801

View EMP Shield, INC.'s full OSHA safety record →