Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRED H. HAMBLET, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of FRED H. HAMBLET, LLC in KEENE WASTE WATER TREATMENT FACILITY 420 AIRPORT RD, SWANZEY, NH 03446 (NAICS 238210). OSHA activity number 346174212.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fred H. Hamblet, LLC — free Get an email when a new federal OSHA severe-injury report for Fred H. Hamblet, LLC is published. One employer, no account, unsubscribe in one click.
Site address
KEENE WASTE WATER TREATMENT FACILITY 420 AIRPORT RD
City
SWANZEY
State
NH
ZIP
03446
Mailing
29 VICTORIA STREET, KEENE, NH 03431
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.417 C

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 19, 2023
Penalty
Initial $4,465 · Current $3,000 Reduced
29 CFR  1926.417(c): Tags were not placed to identify plainly the equipment or circuits being worked on:   Site- On or about August 24, 2022 employees were not protected from electric shock and burns where a tag was not placed on each circuit breaker that was turned off during a scheduled shut down of equipment in the main electric room where work was done.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4465

1926.95 A

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 19, 2023
Abate by
Jan 25, 2023
Penalty
Initial $6,250 · Current $0 Reduced
29 CFR  1926.95(a):Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact:  Site- On or about August 24, 2022 an employee voltage testing 480-volt equipment that had been deenergized was not protected from electric shock and burns where personal protective equipment was not worn.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6250

1926.95 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2023
Abate by
Jan 25, 2023
Penalty
Initial $4,465 · Current $3,000 Reduced
29 CFR  1926.95(d)(1): Except as provided by paragraphs (d)(2) through (d)(6) of this section, the protective equipment, including personal protective equipment (PPE), used to comply with this part, was not provided by the employer at no cost to employee(s).   Site- Employees voltage testing 480-volt equipment and below were required to purchase their own Class 00 electrical insulating gloves, rated for 500 Volts AC and below, and their accessories.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4465

1926.416 A01

Serious Gravity 10 2 instances 3 exposed
Issued
Jan 19, 2023
Penalty
Initial $6,250 · Current $6,250
29 CFR  1926.416(a)(1):Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  a. Site- On or about August 24, 2022 an employee was not protected from electric shock and burns where the employer did not deenergize the 480-volt main switch gear where covers were removed and the employee was performing work inside the switch gear. The employee contacted exposed live parts operating at 480-volts and was electrocuted.  b. Site- On or about August 8, 9, and 16, 2022 employees were not protected from electric shock and burns where the employer did not deenergize the 480-volt main switch gear and ASCO transfer switch while performing work inside the equipment.
Recent events (2)
  • — I (S) $6250
  • — Z (S) $6250

1926.416 A03

Serious Gravity 10 2 instances 3 exposed
Issued
Jan 19, 2023
Penalty
Initial $6,250 · Current $6,250
29 CFR  1926.416(a)(3): Employer did not advise employees of the location of energized electrical power circuits, the hazards involved, and the protective measures to be taken:  a. Site- On or about August 24, 2022 an employee performing work inside the energized 480-volt main switch gear was not protected from electric shock and burns where the employer did not advise the employee on the hazards involved and protective measures to be taken including, but not limited to; deenergizing the 480-volt main switch gear, utilizing the employer's High Voltage Job Site Analysis form,  and implementing the employer's Lockout/Tagout Program. The employee contacted exposed live parts operating at 480-volts and was electrocuted.  b. Site- On or about August 8, 9, and 16, 2022 employees performing work inside the energized 480-volt main switch gear and ASCO transfer switch were not protected from electric shock and burns where the employer did not advise the employee on the hazards involved and protective measures to be taken including, but not limited to; deenergizing the 480-volt equipment, utilizing the employer's High Voltage Job Site Analysis form,  and implementing the employer's Lockout/Tagout Program.
Recent events (2)
  • — I (S) $6250
  • — Z (S) $6250

1926.97 C02 VIII

Other-than-serious 1 instance 1 exposed
Issued
Jan 19, 2023
Abate by
Jan 25, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.97(c)(2)(viii): Electrical protective equipment was not subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table E-4 and Table E-5.  Site- Electrically insulated gloves that were in service were not subjected to periodic electrical tests according to Table E-5 Rubber Insulating Equipment, Test Intervals.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346174212.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.