PUNXSUTAWNEY, PA —
OSHA Inspection: PUNXSUTAWNEY FINISHING WORKS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PUNXSUTAWNEY FINISHING WORKS, INC. in 1857 WOODLAND AVE EXT., PUNXSUTAWNEY, PA 15767 (NAICS 327910). OSHA activity number 346176282.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PUNXSUTAWNEY FINISHING WORKS, INC.
- Site address
- 1857 WOODLAND AVE EXT.
- City
- PUNXSUTAWNEY
- State
- PA
- ZIP
- 15767
- Mailing
- 701 MARTHA STREET, PUNXSUTAWNEY, PA 15767
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327910
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.134 E01
- Issued
- Sep 16, 2022
- Abate by
- Oct 13, 2022
- Penalty
- Initial $4,931 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a)Punxsutawney Finishing Works, Inc., 857 Woodland Ave Extension, Punxsutawney, PA 15767, Abrasive blasting booth area, on or about August 26th, 2022 and times prior thereto: Employees were required to wear supplied air respirators (RPB brand NOVA loose fitting hoods) during work tasks including, but not limited to, abrasive blasting operations. Some employees were not provided with a medical evaluation for respirator use prior to the use of the supplied air respirators. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3000
- — Z (S) $4931
1910.134 I01 II
- Issued
- Sep 16, 2022
- Abate by
- Jan 13, 2023
- Penalty
- Initial $4,931 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.134(i)(1)(ii): Breathing air did not meet requirements for Grade D breathing air as described in the ANSI/Compressed Gas Association Commodity Specification G-7.1-1989: a) Punxsutawney Finishing Works, Inc., 1857 Woodland Ave Extension, Punxsutawney, PA 15767, Abrasive blasting/Compressor area, on or about August 26th, 2022 and times prior thereto: Company employees were utilizing supplied breathing air from two oil-lubricated Quincy air compressors (Model: QST50ANA32S0 Serial # 99412H; and Model: SI02ANA3JG Serial#90611) through a supplied air respirator associated with a Radex airline filter system. The company did not ensure that the compressed breathing air, supplied to company employees, met at least the requirements for Grade D breathing air. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3000
- — Z (S) $4931
1910.134 I05 III
- Issued
- Sep 16, 2022
- Abate by
- Oct 13, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(5)(iii): The compressor's sorbent bed and filters were not maintained and replaced or refurbished periodically as instructed by the manufacturer: a) Punxsutawney Finishing Works, Inc., 1857 Woodland Ave Extension, Punxsutawney, PA 15767, Abrasive blasting/Compressor area, on or about August 26th, 2022 and times prior thereto: Company employees were utilizing supplied breathing air from two oil-lubricated Quincy air compressors (Model: QST50ANA32S0 Serial # 99412H; and Model: SI02ANA3JG Serial#90611) through a supplied air respirator associated with a Radex airline filter system. The company's filter system was not replaced or refurbished per the manufacturers instructions. The last filter changeout for the Radex airline filter system was dated as 4/3/2020 on the Radex airline filter. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 I05 IV
- Issued
- Sep 16, 2022
- Abate by
- Oct 13, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated so as to have a tag maintained at the compressor containing the the signature of the person authorized by the employer to perform the change: a) Punxsutawney Finishing Works, Inc., 1857 Woodland Ave Extension, Punxsutawney, PA 15767, Abrasive blasting/Compressor area, on or about August 26th, 2022 and times prior thereto: Company employees were utilizing supplied breathing air from two oil-lubricated Quincy air compressors (Model: QST50ANA32S0 Serial # 99412H; and Model: SI02ANA3JG Serial#90611) through a supplied air respirator associated with a Radex airline filter system. The company's filter system did not have contain a signature of the person that last performed the filter change out. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Punxsutawney Finishing Works, INC.
View Punxsutawney Finishing Works, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327910)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346176282.