Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CURRENT LIGHTING SOLUTIONS LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CURRENT LIGHTING SOLUTIONS LLC in 1099 IVANHOE RD., CLEVELAND, OH 44110 (NAICS 335121). OSHA activity number 346177975.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Current Lighting Solutions LLC — free Get an email when a new federal OSHA severe-injury report for Current Lighting Solutions LLC is published. One employer, no account, unsubscribe in one click.
Site address
1099 IVANHOE RD.
City
CLEVELAND
State
OH
ZIP
44110
Mailing
1099 IVANHOE RD., CLEVELAND, OH 44110
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335121
Employees
35
Ownership type
A

4 citations on file for this inspection.

1910.120 P08 III C

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 30, 2023
Abate by
Feb 24, 2023
Penalty
Initial $15,625 · Current $0 Reduced

Hazardous substances 2260

29 CFR  1910.120(p)(8)(iii)(C):The employer did not certify that each covered employee had attended and successfully completed the training required in 29 CFR 1910.120(p)(8)(iii):  On or about August 8, 2022, there was a hazardous waste operations and emergency response incident in the waste-water treatment plant that services the LED Lab in the facility at 1099 Ivanhoe Road. Cleveland, OH. The employer failed to ensure that the maintenance employee/s responsible for reacting to and correcting the hazardous waste operations and emergency response incident had adequate training at least annually.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

1910.120 Q01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 30, 2023
Abate by
Feb 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.120(q)(1):The employer did not develop and implement an emergency response plan to handle anticipated emergencies prior to commencement of emergency response operations:  On or about August 8, 2022, there was a hazardous waste operations and emergency response incident in the waste-water treatment plant that services the LED Lab in the facility at 1099 Ivanhoe Road. Cleveland, OH. The employer failed to ensure that the maintenance employee/s responsible for reacting to and correcting the hazardous waste operations and emergency response incident had an emergency response plan to adequately handle anticipated emergencies.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.120 Q11 II

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 30, 2023
Abate by
Feb 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.120(q)(11)(ii):Where cleanup was done on plant property using plant or workplace employees, such employees had not completed the training requirements of 29 CFR 1910.38(a), 1910.134, 1910.1200, and other appropriate safety and health training made necessary by the task they were expected to perform such as personal protective equipment and decontamination procedures:  On or about August 8, 2022, there was a hazardous waste operations and emergency response incident in the waste-water treatment plant that services the LED Lab in the facility at 1099 Ivanhoe Road. Cleveland, OH. The employer failed to ensure that the maintenance employee/s responsible for reacting to and correcting the hazardous waste operations and emergency response incident had adequate training in relation to the employer's emergency action plan.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D03 III B 2

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 30, 2023
Abate by
Feb 24, 2023
Penalty
Initial $15,625 · Current $0 Reduced

Hazardous substances 2260

29 CFR  1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life:  On or about August 8, 2022, there was a hazardous waste operations and emergency response incident in the waste-water treatment plant that services the LED Lab in the facility at 1099 Ivanhoe Road. Cleveland, OH. The employer failed to ensure that the maintenance employee/s responsible for reacting to and correcting the hazardous waste operations and emergency response incident had adequate respiratory protection. The employer provided employee/s with 3M full-face negative pressure respirator with multigas/P100 (model no. 60926-3M) vapor cartridges. During the emergency response, break-through of the respirator cartridge occurred and an employee received respiratory injuries.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

View Current Lighting Solutions LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346177975.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.