Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RICHARDSON-WAYLAND ELECTRICAL COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RICHARDSON-WAYLAND ELECTRICAL COMPANY in 3906 NAAMAN SCHOOL ROAD, GARLAND, TX 75040 (NAICS 238210). OSHA activity number 346183593.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Richardson-Wayland Electrical Company — free Get an email when a new federal OSHA severe-injury report for Richardson-Wayland Electrical Company is published. One employer, no account, unsubscribe in one click.
Site address
3906 NAAMAN SCHOOL ROAD
City
GARLAND
State
TX
ZIP
75040
Mailing
2003 RUSSELL AVENUE SOUTHWEST, ROANOKE, VA 24015
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
224
Ownership type
A

3 citations on file for this inspection.

1926.652 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 4, 2023
Abate by
Jan 31, 2023
Penalty
Initial $13,052 · Current $7,831 Reduced
29 CFR  1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):  a) On or about August 31, 2022, at a jobsite located at 3906 Naaman School Road, Garland, Texas, employees in a 10-foot deep excavation were exposed to caught-in hazards when part of the excavation they worked in was not protected from cave-ins by protective systems.
Recent events (2)
  • — I (S) $7831.2
  • — Z (S) $13052

1926.701 B

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 4, 2023
Abate by
Jan 31, 2023
Penalty
Initial $9,324 · Current $5,594 Reduced
29 CFR  1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement:   a) On or about August 31, 20222, at a jobsite located at 3906 Naaman School Road, Garland, Texas, employees working around a 10-foot deep excavation, were exposed to impalement hazards from a rebar that was not guarded.
Recent events (2)
  • — I (S) $5594.4
  • — Z (S) $9324

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 4, 2023
Abate by
Jan 31, 2023
Penalty
Initial $13,052 · Current $7,831 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) On or about August 31, 2022, at a jobsite located at 3906 Naaman School Road, Garland, Texas, employees in a 10-foot deep excavation were exposed to fall hazards when they used a Werner extension ladder that was not three feet above the upper landing surface.
Recent events (2)
  • — I (S) $7831.2
  • — Z (S) $13052

View Richardson-Wayland Electrical Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346183593.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.