GARLAND, TX —
OSHA Inspection: RICHARDSON-WAYLAND ELECTRICAL COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RICHARDSON-WAYLAND ELECTRICAL COMPANY in 3906 NAAMAN SCHOOL ROAD, GARLAND, TX 75040 (NAICS 238210). OSHA activity number 346183593.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RICHARDSON-WAYLAND ELECTRICAL COMPANY
- Site address
- 3906 NAAMAN SCHOOL ROAD
- City
- GARLAND
- State
- TX
- ZIP
- 75040
- Mailing
- 2003 RUSSELL AVENUE SOUTHWEST, ROANOKE, VA 24015
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 224
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.652 A01
- Issued
- Jan 4, 2023
- Abate by
- Jan 31, 2023
- Penalty
- Initial $13,052 · Current $7,831 Reduced
General-duty citation text
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): a) On or about August 31, 2022, at a jobsite located at 3906 Naaman School Road, Garland, Texas, employees in a 10-foot deep excavation were exposed to caught-in hazards when part of the excavation they worked in was not protected from cave-ins by protective systems.
Recent events (2)
- — I (S) $7831.2
- — Z (S) $13052
1926.701 B
- Issued
- Jan 4, 2023
- Abate by
- Jan 31, 2023
- Penalty
- Initial $9,324 · Current $5,594 Reduced
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: a) On or about August 31, 20222, at a jobsite located at 3906 Naaman School Road, Garland, Texas, employees working around a 10-foot deep excavation, were exposed to impalement hazards from a rebar that was not guarded.
Recent events (2)
- — I (S) $5594.4
- — Z (S) $9324
1926.1053 B01
- Issued
- Jan 4, 2023
- Abate by
- Jan 31, 2023
- Penalty
- Initial $13,052 · Current $7,831 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about August 31, 2022, at a jobsite located at 3906 Naaman School Road, Garland, Texas, employees in a 10-foot deep excavation were exposed to fall hazards when they used a Werner extension ladder that was not three feet above the upper landing surface.
Recent events (2)
- — I (S) $7831.2
- — Z (S) $13052
More inspections at Richardson-Wayland Electrical Company
View Richardson-Wayland Electrical Company's full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346183593.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.