Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ROSS INDUSTRIAL, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ROSS INDUSTRIAL, LLC in 104 NORTH MAPLE AVENUE, LEOLA, PA 17540 (NAICS 332312). OSHA activity number 346185358.

Watch Ross Industrial, LLC — free Get an email when a new federal OSHA severe-injury report for Ross Industrial, LLC is published. One employer, no account, unsubscribe in one click.
Site address
104 NORTH MAPLE AVENUE
City
LEOLA
State
PA
ZIP
17540
Mailing
104 NORTH MAPLE AVENUE, LEOLA, PA 17540
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
80
Ownership type
A

5 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4687.00 · Current $3515.00 Reduced
29 CFR  1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces were kept in a clean, orderly, and sanitary condition:  (a) Blaster 2 Unloading Area - Excess blast media fell off parts and settled into the porous concrete floor, causing the floor to become slippery at the unloading end of Blaster 2, exposing employees to slip and fall hazards, on or about August 31, 2022.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $3515.25
  • — Z (S) $4687

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6250.00 · Current $4688.00 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Near the Entrance into the Plant from the Office Area - The Armstrong-Blum Marvel number 8 vertical band saw, used to cut metal, did not have the upper band saw wheel fully encased by guarding, exposing employees to a caught in hazard from rotating parts, on or about July 31, 2022.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $4687.5
  • — Z (S) $6250

1910.303 B02

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4687.00 · Current $3515.00 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   (a) Near the Parts Oven - The employer used receptacles on a relocatable power tap (a.k.a., power strip or surge protector) to power lights and had the relocatable power tap supplied through an extension cord.  The UL listing for the relocatable power tap specifies using the device for supplying power to low amperage electronic equipment and specifies not using the device connected to an extension cord, exposing employees to an electrical hazard, on or about August 31, 2022.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $3515.25
  • — Z (S) $4687

1910.305 G01 IV A

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   (a) Near the Parts Oven - As a substitute for fixed wiring, the employer powered lights through the use of receptacles on a relocatable power tap (a.k.a., power strip or surge protector), with the relocatable power tap supplied through an extension cord, exposing employees to an electrical hazard, on or about August 31, 2022.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   (a) Near the Parts Oven - The flexible cord on a light had no strain relief in that the cord had frayed at the plug end, exposing employees to an electrical hazard, on or about August 31, 2022.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View ROSS INDUSTRIAL, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346185358.