APPLETON, WI —
OSHA Inspection: PRO RESTORATION LLC
Special Programs inspection · Safety discipline
At a glance
On , OSHA opened a special Programs safety inspection of PRO RESTORATION LLC in 600 E CARRINGTON LANE, APPLETON, WI 54913 (NAICS 238160). OSHA activity number 346185879.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRO RESTORATION LLC
- Site address
- 600 E CARRINGTON LANE
- City
- APPLETON
- State
- WI
- ZIP
- 54913
- Mailing
- 9934 N ALPINE ROAD, SUITE 106, MACHESNEY PARK, IL 61115
What kind of inspection was it?
- Inspection type
- Special Programs (K)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 1
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.20 B02
- Issued
- Sep 30, 2022
- Abate by
- Oct 31, 2022
- Penalty
- Initial $3,108 · Current $3,108
General-duty citation text
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers. On or about August 29, 2022, at a worksite located at 600 E. Carrington Ln, Appleton Wisconsin 54913: the employer did not address construction hazards by having frequent and regular inspections of the worksite by a competent person to ensure sub-contractors were following company and OSHA safety regulations to include the use of fall protection.
Recent events (2)
- — I (S) $3108
- — Z (S) $3108
1926.501 B13
- Issued
- Sep 30, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. On or about August 29, 2022, at a worksite located at 600 E. Carrington Ln, Appleton Wisconsin 54913, employees were performing residential roofing activities without any form of conventional fall protection while exposed to falls of approximately 18 feet seven inches. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D15
- Issued
- Sep 30, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15):Anchorages used for attachment of personal fall arrest equipment shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, or shall be designed, installed, and used as follows: On or about August 29, 2022, at a worksite located at 600 E. Carrington Ln, Appleton Wisconsin 54913: two employees was performing residential roofing activities while being tied into one anchor point with multiple lanyards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D17
- Issued
- Sep 30, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(17): The attachment point of the body belt shall be located in the center of the wearer's back. The attachment point of the body harness shall be located in the center of the wearer's back near shoulder level, or above the wearer's head. On or about August 29, 2022, at a worksite located at 600 E. Carrington Ln, Appleton Wisconsin 54913: one employee was performing residential roofing activities with a fall hazard of 18 feet 7 inches and did not attach their fall arrest components to a point near the center of their back.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Sep 30, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about August 29, 2022, at a worksite located at 600 E. Carrington Ln, Appleton Wisconsin 54913: employees were utilizing two metal extension ladders that did not extend three feet above the roof surface. a. Five employees were utilizing a metal extension ladder at the front of the house and were exposed to a fall hazard of approximately 18 feet 8 inches as the ladder was used for accessing and egressing the roof from the ground and did not extend three feet above the roof surface. b. Two employees were utilizing a metal extension ladder at the side of the house and were exposed to a fall hazard of approximately nine feet one inch as the ladder was used for accessing and egressing the roof from the ground and did not extend three feet above the roof surface.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at PRO Restoration LLC
View PRO Restoration LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346185879.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.