MEDFORD, MA —
OSHA Inspection: FA CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FA CONSTRUCTION, INC. in 12 BRAEMORE RD., MEDFORD, MA 02155 (NAICS 238130). OSHA activity number 346190366.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FA CONSTRUCTION, INC.
- Site address
- 12 BRAEMORE RD.
- City
- MEDFORD
- State
- MA
- ZIP
- 02155
- Mailing
- 15 PHANEUF ST., MIDDLETON, MA 01949
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.501 B13
- Issued
- Jan 12, 2023
- Penalty
- Initial $4,351 · Current $4,125 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Location - 12 Braemore Rd., Medford, MA On or about 9/1/2022, employees on a extension ladder placed on a upper roof were not protected from falls to a lower level while transitioning from the ladder onto the roof.
Recent events (3)
- — F (S) $4125
- — C (S) $4351
- — Z (S) $4351
1926.451 F07
- Issued
- Jan 12, 2023
- Abate by
- Apr 13, 2023
- Penalty
- Initial $4,351 · Current $4,125 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person. Location - 12 Braemore Rd., Medford, MA On or about 9/1/2022, employees were exposed to fall hazards while working from a pump jack scaffold that was not erected under the supervision of a competent person.
Recent events (3)
- — F (S) $4125
- — C (S) $4351
- — Z (S) $4351
1926.451 G01
- Issued
- Jan 12, 2023
- Penalty
- Initial $4,351 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Location - 12 Braemore Rd., Medford, MA On or about 9/1/2022, employees on a pump jack scaffold were not protected against falls of greater than 10 feet above a lower level.
Recent events (3)
- — F (S) $0
- — C (S) $4351
- — Z (S) $4351
1926.451 B04
- Issued
- Jan 12, 2023
- Penalty
- Initial $3,108 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(4): Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm). Location - 12 Braemore Rd., Medford, MA On or about 9/1/2022, employees were exposed to fall hazards while working from a scaffold platform that did not extend over a support.
Recent events (3)
- — F (S) $0
- — C (S) $3108
- — Z (S) $3108
1926.451 B05 II
- Issued
- Jan 12, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. Location - 12 Braemore Rd., Medford, MA On or about 9/1/2022, employees were exposed to fall hazards while working from a scaffold platform that extended more than 18 inches over a support.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 C02
- Issued
- Jan 12, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. Location - 12 Braemore Rd., Medford, MA On or about 9/1/2022, employees were exposed to fall hazards while working from a pump jack scaffold, where the scaffold poles did not bear on mud sills.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Jan 12, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. Location - 12 Braemore Rd., Medford, MA On or about 9/1/2022, employees on a pump jack scaffold were not provided proper access/egress.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.452 J02
- Issued
- Jan 12, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. Location - 12 Braemore Rd., Medford, MA On or about 9/1/2022, employees were exposed to fall hazards while working from a pump jack scaffold where the poles were not secured at the bottom.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238130)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346190366.