Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MYS, INCORPORATED

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of MYS, INCORPORATED in I 290 EXIT RAMP FOR BIESTERFIELD RD., ELK GROVE VILLAGE, IL 60007 (NAICS 237990). OSHA activity number 346193394.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MYS, Incorporated — free Get an email when a new federal OSHA severe-injury report for MYS, Incorporated is published. One employer, no account, unsubscribe in one click.
Establishment
MYS, INCORPORATED
Site address
I 290 EXIT RAMP FOR BIESTERFIELD RD.
City
ELK GROVE VILLAGE
State
IL
ZIP
60007
Mailing
12416 SOUTH HARLEM AVENUE, PALOS HEIGHTS, IL 60463
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237990
Employees
13
Ownership type
A

4 citations on file for this inspection.

1926.1153 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 12, 2023
Abate by
Feb 15, 2023
Penalty
Initial $4,144 · Current $2,901 Reduced
29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the tasks in Table 1,  unless the employer assessed and limited the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.  a) On September 1, 2022, MYS, Incorporated, did not implement engineering controls and work practices, as specified in Table 1 of 1926.1153 when an employee was cutting precast concrete containing silica, with a portable handheld  gas-powered Stihl saw.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $2900.8
  • — Z (S) $4144

1926.1153 D02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 12, 2023
Abate by
Feb 15, 2023
Penalty
Initial $0 · Current $0
29 CFR 1926.1153(d)(2)(i): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section:  a) On September 1, 2022, MYS Incorporated,  did not assess the exposure of  employee(s) who may be exposed to crystalline silica when cutting precast concrete using a portable handheld  gas-powered Stihl saw.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1153 G01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 12, 2023
Abate by
Feb 15, 2023
Penalty
Initial $0 · Current $0
29 CFR 1926.1153(g)(1): The employer did not establish and implement a written exposure control plan:  a) On September 1, 2022, MYS Incorporated, did not establish and implement a written silica exposure control plan that complied with the requirements of 1926.1153(g)(1)(i) through (iv) when an employee was cutting precast concrete containing crystalline silica with a handheld gas-powered Stihl saw.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1153 G04

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 12, 2023
Abate by
Feb 15, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.1153(g)(4):The employer did not designate a competent person to make frequent and regular inspections of job sites, materials, and equipment to implement the written exposure control plan:  a) On September 1, 2022, MYS Incorporated., did not designate a competent person to make frequent and regular inspection of the job site, materials, and equipment to implement a written exposure plan for silica at a jobsite located at I 290 Exit Ramp for Biesterfield Rd. when employee(s) were cutting precast concrete using a portable handheld  gas-powered Stihl saw.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View MYS, Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346193394.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.